3.
S
ETUP
AC Power
The Intimidator Scan/Barrel 305 IRC have auto-ranging power supplies that work with an input
voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (
circuit breaker, power outlet, and wiring), use
the values listed on the label affixed to the product’s back panel, or refer to the product’s
Specifications. The listed current rating indicates the product
’s average current draw under
normal conditions.
The Intimidator Scan/Barrel 305 IRC can be power linked via the IEC and Edison outlets in its
base.
• Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure circuit has an appropriate electrical ground to avoid the risk of electrocution or
fire.
• Never connect the product to a
rheostat (variable resistor) or dimmer, even if the
rheostat or dimmer serves only as a 0 to 100% switch.
• To eliminate wear and improve its lifespan, during periods of non-
use completely
disconnect from power via breaker or by unplugging it.
Fuse
Replacement
Make sure product is not connected to a power source.
1. Place the tip of a flat-head screwdriver into the slot in the fuse holder.
2. Turn the screwdriver counterclockwise and the fuse holder will come loose.
3. Pull the fuse holder out of the product.
4. Pull the blown fuse out of the fuse holder.
5. Place a new fuse of the exact same type and rating into the fuse holder.
6. Insert the fuse holder into the product.
7. Place the tip of a flat-head screwdriver into the slot in the fuse holder.
8. Turn the screwdriver clockwise and the fuse holder will tighten into place.
• Disconnect the product from power before replacing the fuse.
• Use only the fuse listed in the Technical Specifications section or on the
specifications sticker on the product.
• A spare fuse is not included.