Edition Notes The Maverick Force 2 Profile User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the Maverick Force 2 Profile as of the release date of this edition. Trademarks CHAUVET, the Chauvet logo and Maverick Force 2 Profile are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries.
Table of Contents TABLE OF CONTENTS 1. Before You Begin ......................................................................................... What Is Included ...................................................................................................... Claims ...................................................................................................................... Text Conventions .....................................................................................................
Table of Contents Configuration (Settings) ........................................................................................... 22 Pan Reverse .................................................................................................................. Tilt Reverse .................................................................................................................... Screen Reverse ......................................................................................................
Before You Begin 1. Before You Begin What Is Included • • Maverick Force 2 Profile Seetronic Powerkon IP65 Power Cord • • Omega Brackets with Mounting Hardware Quick Reference Guide Claims Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet.
Before You Begin Safety Notes Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs. All applicable local codes and regulations apply to proper installation of this product.
Introduction 2. Introduction Description The Maverick Force 2 Profile is a lightweight, tour-grade moving head with a big presence. The powerful product features an output of over 20,000 lumens and an artillery of speedy effects housed in a deceptively compact frame, under 60lbs. The Maverick Force 2 Profile features CMY + CTO color-mixing, a color wheel with a CTB and CRI option, and an extensive zoom range of 7 to over 50 degrees that maintains a flat field of focus even when fully wide.
Introduction Product Dimensions 15.11 in 384 mm 11.22 in 285 mm 17.79 in 452 mm 21.72 in 552 mm 13.9 in 353 mm 26.38 in 670 mm 4.51 in 114 mm 15.51 in 394 mm 10.71 in 272 mm 10.0 in 254 mm Page 4 of 31 Maverick Force 2 Profile User Manual Rev.
Setup 3. Setup AC Power The Maverick Force 2 Profile has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Setup Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/. Orientation Always mount this product in a safe position, making sure there is adequate room for ventilation, configuration, and maintenance. Rigging Chauvet recommends using the following general guidelines when mounting this product.
Setup Signal Connections The Maverick Force 2 Profile can receive a DMX, Art-Net™, or sACN, signal. The Maverick Force 2 Profile has 2 Amphenol XLRnet through ports, and 3- and 5-pin DMX in and out ports. If using other compatible products with this product, you can control each individually with a single controller. Control Personalities The Maverick Force 2 Profile uses a 3 or 5-pin DMX data connection, WDMX, Art-Net™, or sACN for its 2 control personalities: Dmx Mode 33 CH and Dmx Mode 50 CH.
Operation 4. Operation Touchscreen Control Panel The Maverick Force 2 Profile has a touchscreen display as well as 6 control buttons. Navigate the menu structure by pressing the buttons, touching the images of the buttons on the sides of the display, or touching the desired menu option on the display directly. The touchscreen can be locked and calibrated through the Setup options in the menu. (See Touchscreen Calibration and Touchscreen Lock.
Operation Menu Map Refer to the Maverick Force 2 Profile product page on www.chauvetprofessional.com for the latest menu map. Main Level Programming Levels Description Address 001–480 Sets the starting address Manual Manually set IP address IP Mode DHCP Network sets IP address Static Product sets IP address 000–255 (Art-Net™) Network Universe Sets the universe 001–256 (sACN) Setup Sets the IP address in Ip _ _ _._ _ _._ _ _._ _ _ Manual mode Sets the Subnet Mask in SubMask _ _ _._ _ _._ _ _.
Operation Main Level Programming Levels Lock Screen Swap XY WDMX Reset Description NO YES NO YES NO YES 30S Backlight Timer 1M 5M Loss of Data ON Hold Close Auto Full ECO Fans Settings (cont.) TV35 Dimmer Curve PWM Option LED POWER Min Zoom Focus Preset Select Preset Sync USB Update Page 10 of 31 TV25 Linear Square I Squa SCurve Linear2 600Hz 1200Hz 4000Hz 6000Hz 15000Hz 064–255 NO YES PRESET A PRESET B PRESET C NO YES NO YES Lock the buttons and touch screen.
Operation Main Level Settings (cont.
Operation Main Level Test (cont.) Manual Test (cont.
Operation Main Level Information (cont.) Channel Information (cont.) Programming Levels Color Gobo Gobo Rotate Gobo Index Gobo2 Gobo2 Rotate Gobo2 Index Blade1- 1 Blade1- 1 Fine Blade1- 2 Blade1- 2 Fine Blade2- 1 Blade2- 1 Fine Blade2- 2 Blade2- 2 Fine Blade3- 1 Blade3- 1 Fine Blade3- 2 Blade3- 2 Fine Blade4- 1 Blade4- 1 Fine Blade4- 2 Blade4- 2 Fine Blade Rotate Blade.
Operation Configuration (DMX, Art-Net™, sACN) Use control configurations to operate the product with a DMX, Art-Net™, or sACN controller. Control Mode The Maverick Force 2 Profile works with wired DMX, WDMX, Art-Net™, and sACN control signals. To select which protocol to use: 1. Go to the Settings main level. 2. Select the ControlMode option. 3. Select the desired protocol, from DMX, WDMX, ArtNet, or sACN. • See the WDMX Reset section for further setup of WDMX.
Operation Control Channel Assignments and Values Dmx Mode 50 CH Channel Function 1 Pan 2 Fine Pan 3 Tilt 4 Fine Tilt 5 Pan/Tilt Speed 6 Dimmer 7 Fine Dimmer 8 Shutter 9 Virtual Strobe 10 11 12 13 Cyan Magenta Yellow CTO 14 Color Wheel 15 Gobo Wheel 1 Value 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 003 004 007 008 076 077 145 146 215 216 255 000 001 002 128 129 255 000 255 000 255 000 255 000 255 000 006 007 013 014 020 021 027 028
Operation Channel Function 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Value 000 063 064 145 Gobo 1 Rotate 146 149 150 231 232 255 Gobo Wheel 1 Indexing 000 255 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 Gobo Wheel 2 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 191 192 255 000 063 064 145 146 149 Gobo 2 Rotate 150 231 232 255 Gobo Wheel 2 Indexing 000 255 Blade 1-1 000
Operation Channel Function 41 Auto Focus 42 43 Zoom Fine Zoom 44 Prism 45 Prism Rotate 46 Iris 47 Frost 48 CMY Macro 49 CMY Macro Speed Value 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 190 191 210 211 255 000 255 000 255 000 004 005 255 000 127 128 189 190 193 194 255 000 063 064 127 128 191 192 255 000 255 000 009 010 255 000 255 Maverick Force 2 Profile User Manual Rev.
Operation Channel Function 50 Control Value 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 095 096 103 104 111 112 119 120 127 128 131 132 135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 217 218 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 Percent/Setting No function XY blackout C blackout G blackout XY/C blackout XY/G blackout XY/C/G blackout No function X reset Y reset
Operation Channel Function 11 Yellow 12 CTO 13 Color Wheel 14 Gobo Wheel 1 15 Gobo 1 Rotate Value 000 255 000 255 000 006 007 013 014 020 021 027 028 034 035 041 042 048 049 059 060 187 188 219 220 223 224 255 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 191 192 255 000 063 064 145 146 149 150 231 232 255 Maverick Force 2 Profile User Manual
Operation Channel Function 16 Gobo Wheel 2 17 Gobo 2 Rotate 18 19 20 21 22 23 24 25 26 27 28 Blade 1-1 Blade 1-2 Blade 2-1 Blade 2-2 Blade 3-1 Blade 3-2 Blade 4-1 Blade 4-2 Frame Rotate Focus Zoom 29 Prism 30 Prism Rotate 31 Iris 32 Frost Page 20 of 31 Value 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 191 192 255 000 063 064 145 146 149 150 231 232 255 000 2
Operation Channel Function 33 Control Value 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 095 096 103 104 111 112 119 120 127 128 131 132 135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 217 218 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 Maverick Force 2 Profile User Manual Rev.
Operation Configuration (Settings) Pan Reverse To set the orientation of the pan: 1. Go to the Settings main level. 2. Select the Pan Reverse option. 3. Select from NO (normal pan motion), or YES (reversed pan motion). Tilt Reverse To set the orientation of the tilt: 1. Go to the Settings main level. 2. Select the Tilt Reverse option. 3. Select from NO (normal tilt motion), or YES (reversed tilt motion). Screen Reverse To set the orientation of the display: 1. Go to the Settings main level. 2.
Operation Display Backlight Timer To set the length of time before an inactive display will turn off: 1. Go to the Settings main level. 2. Select the Backlight Timer option. 3. Select the length of the backlight timer, from 30S (30 seconds), 1M (1 minute), 5M (5 minutes), or ON (always on). Loss of Data To set how the product reacts to a loss in control signal data: 1. Go to the Settings main level. 2. Select the Los of Data option. 3.
Operation Preset Synchronization To transfer saved Presets from one Maverick Force 2 Profile to another: 1. Connect the Maverick Force 2 Profile products to receive the Presets by a DMX daisy chain. 2. Make the Maverick Force 2 Profile with the Presets to transfer the first in the DMX daisy chain. 3. Power on all of the products. 4. Set all of the products to a Control Mode other than WDMX. (DMX, ArtNet, or sACN) 5. On the Maverick Force 2 Profile with the Presets, go to the Settings main level. 6.
Operation System Information The information section of the menu displays statistics and the current status of the product’s various functions. To view these information sections: 1. Go to the Information main level. 2.
Operation Gobo Wheels Gobo Wheel 1 Gobo Wheel 2 Gobo Wheel Gobo # Description Gobo Wheel Gobo # Description 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 Sail Boats Radial Dot Dots Bolts Shower Glass Ballistic Glass Four Eyes 2 Spiral Abstracts Brick Wall Chess Granny Sue Color Weave Indigo Square Breakup Gobo Dimensions Page 26 of 31 Gobo Wheel 1 Gobo Wheel 2 25.5 mm 25.5 mm 20 mm 18.5 mm IMAGE IMAGE Maverick Force 2 Profile User Manual Rev.
Operation Gobo Replacement The gobos in gobo wheel 1 are removable from their gobo holders. This operation is quite simple, although it requires the technician to carefully follow the recommended procedure. • Make sure to disconnect the product’s power cord before replacing a gobo. • Always replace a gobo with a gobo of the same dimensions. • When inserting a glass gobo, always make sure that the shiny side of the gobo (glass base) faces the lamp.
Maintenance 5. Maintenance Product Maintenance Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency. To clean the product, follow the instructions below: 1.
Technical Specifications 6. Technical Specifications Dimensions and Weight Length 15.51 in (394 mm) Width 10.71 in (272 mm) Height 26.38 in (670 mm) Weight 57.3 lb (26 kg) Note: Dimensions in inches are rounded. Power Power Supply Type Range Switching (internal) 100 to 240 VAC, 50/60 Hz Parameter 100 V, 60 Hz Consumption 800 W Operating Current 8.01 A Fuse/Breaker F 13 A, 250 V 120 V, 60 Hz 780 W 6.
Returns Returns Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags. Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return. To submit a service request online, go to www.chauvetprofessional.com/service-request. Clearly label the package with an RMA number.
Contact Us Contact Us General Information Technical Support Chauvet World Headquarters Address: 5200 NW 108th Ave. Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll Free: (800) 762-1084 Voice: (844) 393-7575 Fax: (954) 756-8015 Email: chauvetcs@chauvetlighting.com Website: www.chauvetprofessional.com Chauvet Europe Ltd Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0) 1773 511115 Fax: +44 (0) 1773 511110 Email: UKtech@chauvetlighting.