5. TECHNICAL INFORMATION
Hazer Maintenance
Do not allow the haze machine to become clogged. After every 40 hours of continuous
operation, use CHAUVET® Fog Cleaner Quart (FCQ) through the system to prevent the
accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all haze fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-ventilated area until the tank is empty.
6. Refill with haze fluid to continue using the hazer. Run the machine briefly to clear any
cleaning solution from the pump and heater.
FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET® to clean your
Amhaze™ Studio
. Make sure you use FCQ regularly to increase the life of your
hazer.
Do not spin the fans using compressed air because you could damage the hazer.
Storage
Before storing the hazer, run FCQ through the system as described in the cleaning
procedure above; however,
only follow steps 1 through 5. Do not refill the tank with hazer
fluid if storing the hazer. Cleaning the system prior to storage will help prevent any
particles from condensing inside the pump or heater while not in use.
Test-run your Amhaze™ Studio o
n a monthly basis to achieve the best
performance.