User manual

Operation
-8- Amhaze™ User Manual Rev. 05
Startup
The Amhaze™ does not have an On/Off switch. As soon as you connect the Amhaze™ to
the power outlet, it will start operating.
To start up the Amhaze™, do the following:
Insert the Neutrik® powerCON® A connector of the power input cord into the lockable 1.
(blue) socket on the back of the Amhaze™.
Turn the connector right until it locks in position. 2.
Plug the power input cords to a suitable power outlet (the display will showWarm Up 3.
Cycle”).
Wait about two minutes for the warm-up to complete. During this time, the Amhaze™ 4.
will not produce any haze.
After warming up, the display will showREADY TO HAZE FLUID SENSOR 5.
ON/OFF”.
Press <VOLUME>. 6.
Adjust haze output volume by using the <UP> or <DOWN>. 7.
Press <STOP> again to stop haze production. 8.
Repeat the Startup procedure after transporting the Amhaze™ or after a fluid refill.
Timer
Operation
When in Timer mode, the Amhaze™ will produce haze in pre-configured time intervals
defined by the TIME INTERVAL and TIME DURATION menu options. In addition, the
output volume during Timer mode is set by the TIMER VOLUME menu option. See the
Programming
section for details about how to configure these parameters.
To operate in Timer mode, do the following:
Press <TIMER> (the display will show a countdown of the Interval Timer). 1.
When the counter reaches zero (0), the Amhaze™ will start producing haze. 2.
The hazing duration is set by the TIMER DURATION menu option. 3.
The hazing volume during Timer mode is set by the TIMER VOLUME menu option. 4.
This cycle will repeat itself until you press <STOP> again or until the Amhaze™ runs 5.
out of fluid.
The Amhaze™ can produce continuous haze without reheating. This means that
hazing will start immediately each time the Interval timer reaches zero (0).
Continuous
Operation
In the Continuous mode, the Amhaze™ will produce haze without interruptions. The output
volume is set in the VOLUME MODE OUT menu option. See the Programming section for
details about how to configure this parameter.
To operate in Continuous mode, do the following:
Press <VOLUME> (the display will show VOLUME MODE OUT and the percentage 1.
of the output volume).
This mode will continue itself until you press <STOP> or until the Amhaze™ runs out 2.
of fuel.
The Amhaze™ can produce continuous haze without reheating. This means that
hazing will start immediately each time you press <VOLUME>.