User manual

Operation
AmHaze™ User Manual Rev. 01g -9-
Programming
The Programming mode allows you to change the options that affect the various operating
modes as well as setting the DMX address.
Timer Mode
Parameters
These parameters determine the on and off intervals as well as the output volume when
the AmHaze™ is in Timer mode.
To configure these parameters do the following:
1) Press <FUNCTION> repeatedly until TIME BETWEEN shows on the display.
2) Use <UP> or <Down> to set the time off timer (1~200 s).
3) Press <FUNCTION> repeatedly until TIME ON shows on the display.
4) Use <UP> or <Down> to set the time on (1~200 s).
5) Press <FUNCTION> repeatedly until TIMER VOLUME shows on the display.
6) Use <UP> or <Down> to set the haze volume (1~100%).
Continuous Mode
Parameters
These parameters affect the haze and fan volumes when the AmHaze™ operates in
Continuous mode.
To configure these parameters do the following:
1) Press <FUNCTION> repeatedly until PUMP VOLUME shows on the display.
2) Use <UP> or <Down> to set the haze volume (1~100%).
3) Press <FUNCTION> repeatedly until FAN VOLUME XX% shows on the display.
4) Use <UP> or <Down> to set the fan volume (1~100%).
During stand-by periods, the fan volume resets to 20% to keep a low noise level.
DMX Address
This parameter determines the DMX starting address of the AmHaze™. Refer to the DMX
Values section to learn the values and assignments of the AmHaze’s 2-channel mode.
The following steps will show you how to configure the DMX starting address.
1) Press <FUNCTION> repeatedly until DMX-512 shows on the display.
2) Use <UP> or <Down> to set the DMX starting address (001~511).
DMX Values
2-Channel Mode
Channel Function Value Percent/Setting
1 Output Volume
000
ó
005
067
ó
255
No output
2~100%
2
Fan Volume
000
ó
255
20~100%