User manual
Setup
AmHaze™ User Manual Rev. 01g -5-
3. Setup
AC Power
This product comes in two models, each with a fixed input voltage power supplies, either
120 V, 60 Hz or 230 V, 50 Hz. Therefore, you have to order the correct model for the line
voltage in your area.
Make sure that you are connecting this product to the proper voltage, as per the
specifications in this guide, the product’s user manual, or on the product’s sticker.
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
To determine the power requirements for the AmHaze™ see the label affixed to the side of
the product. Alternatively, you may refer to the Technical Specifications chart in the
Technical Information chapter of this manual.
The listed current rating indicates the maximum current draw during normal operation. For
more information, you may download the “Sizing the Circuit Breakers” document from the
CHAUVET® Web site.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if
the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The AmHaze™ comes with a power input cord terminated with a Neutrik® powerCON® A
connector on one end an Edison plug on the other end (US market). If the power input cord
that came with your product has no plug or you need to change the plug, use the table
below to wire the new plug.
Connection Wire (US) Wire (Europe) Screw Color
AC Live Black Brown Yellow or Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
Disconnect this product from the power outlet before resetting the breaker.
Resetting the
Breaker
This product is equipped with a resettable circuit breaker on the power input circuit.
If the breaker trips, all sections of this product will lose power. Please see the instructions
below for resetting this breaker.
1) Remove the power cord from mains power.
2) Allow unit to cool for 15 minutes.
3) After 15 minutes, you may attempt to reset the breaker by pressing the button with
your index finger.
4) Plug the product’s power cord into the power outlet and continue using as
recommended.
If the breaker does not reset (the breaker button will not remain inserted), contact
CHAUVET® immediately, as this indicates a possible internal malfunction.