Edition Notes Edition Notes The Legend™ 330SR Spot User Manual Rev. 2 covers the description, safety precautions, installation, programming, operation, and maintenance of the Legend™ 330SR Spot. CHAUVET® released this edition of the Legend™ 330SR Spot User Manual in July 2014. Trademarks CHAUVET® is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET® or Copyright Notice Manual Use Chauvet).
Table of Contents Table of Contents 1. Before You Begin ...................................................................................................................................... 1 What Is Included ........................................................................................................................................................... 1 Claims ........................................................................................................................................
Table of Contents DMX Values (cont.) ..................................................................................................................................................... 24 DMX Values (cont.) ..................................................................................................................................................... 25 DMX Values (cont.) ...................................................................................................................................
Before You Begin 1. BEFORE YOU BEGIN What Is Included Claims Manual Conventions • Legend™ 330SR Spot • Neutrik® powerCON® power cord • 2 Omega brackets with mounting hardware • Warranty Card • Quick Reference Guide Carefully unpack the product immediately and check the box to make sure all the parts are in the package and are in good condition.
Before You Begin Product At A Glance Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Safety Notes x x x P x Auto Programs Auto-Ranging Power Supply Replaceable Fuse User-Serviceable x P P x Read all the following Safety Notes before working with this product. These notes include important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts.
Introduction 2. INTRODUCTION Description The Legend™ 330SR Spot is a compact, electronic, moving yoke beam product equipped with a 330 watt X8 lamp. It includes a color wheel with 7 colors plus white. It also includes a rotating 3-facet prism, frost, remote focus, and 2 gobo wheels for gobo morphing.
Introduction Overview Power Switch Fuse Data In DMX Control Panel DMX Data Out Front View Power In Rear View Handle Top View -4- Side View Legend™ 330SR Spot User Manual Rev.
Introduction Dimensions 15.12 in 384 mm 22.01 in 428 mm 4.76 in 121 mm 22.01 in 559 mm 17.13 in 435 mm 13.54 in 344 mm 15.12 in 384 mm 10.63 in 270 mm 25.55 in 649 mm 19.80 in 503 mm Legend™ 330SR Spot User Manual Rev.
Setup 3. SETUP AC Power Each Legend™ 330SR Spot has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Legend™ 330SR Spot, refer to the label affixed to the product. You can also refer to the Technical Specifications chart in this manual. The listed current rating indicates the maximum current draw during normal operation. For more information, you may download Sizing Circuit Breakers from the CHAUVET® website: www.
Setup Gobo Wheel The Legend™ 330SR Spot includes two gobo wheels: 8 rotating gobos plus open on wheel 1 and 14 fixed gobos plus open on wheel 2. The diagram shows the gobo number on the wheel, as numbered in the DMX Values tables. 17.8 mm 14.0 mm 8 7 6 Gobo Wheel 1 5 1 2 4 3 Gobo Dimensions Gobo Wheel 1 6 5 7 4 3 8 2 9 Gobo Wheel 2 1 10 11 12 13 14 The gobos on Gobo Wheel 2 are not removeable. Legend™ 330SR Spot User Manual Rev.
Setup Color Wheel The Legend™ 330SR Spot includes one color wheel with 7 fixed colors plus open (white), as indicated below. The diagram shows the color number on the wheel, as numbered in the DMX Values tables. Open (White) 2 1 7 3 4 -8- 5 6 Legend™ 330SR Spot User Manual Rev.
Setup Lamp Replacement The Legend™ 330SR Spot is equipped with an Osram Sirius 330W X8 lamp. Follow the procedure below to safely change the lamp. Disconnect the product from power before opening. Procedure 1. Turn the product off and disconnect it from power. Wait at least 15 minutes for the lamp to cool down. 2. Remove back cover using the 2 Phillips-head ¼-turn screws. 3. Orient the rear of the product so that the spring clip inside is facing downward.
Setup Procedure 4. Using the lamp base, push the lamp down against the spring clips and then roll the lamp out the top. (Cont.) 5. Remove the 2 wires connected to the lamp by the spade terminals. Spade Connectors 6. Reverse the steps above to install the new lamp. Do not touch the glass with bare hands.
Setup Mounting Orientation Before mounting this product, read and follow the Safety Notes. For our CHAUVET® line of mounting clamps, go to http://trusst.com/productcategory/base-plates-accessories-clamps/. Always mount this product in a safe position and make sure there is adequate room for ventilation, configuration, and maintenance. Rigging CHAUVET® recommends using the following general guidelines when mounting this product.
Operation 4.
Operation Menu Map Main Level Programming Levels DMX Address DMX Functions P/T Feedback Fixture Setting Bl.o. P/T Moving Bl.o. Color Change Bl.o.
Operation Menu Map (Cont.
Operation DMX Functions From the Main Menu, highlight DMX Functions and press (a new menu with the DMX functions will open). DMX Address 1. Highlight DMX Address. 2. To change the current address, press . a. Change the starting address (001–512). b. Accept the new value. DMX Mode 1. Highlight DMX Channel Mode. 2. To change the current mode, press . a. Select a DMX mode (Mode1/Mode2). b. Accept the selected option. View DMX Values 1. Highlight View DMX Value. 2. Press . a.
Operation Lamp Settings From the Main Menu, highlight Lamp Settings and press . The lamp will not turn on if the ambient temperature is 104 ºF (40 ºC) or higher. Lamp On/Off 1. Highlight On/Off. 2. To turn the lamp on or off, press . a. Select ON to turn the lamp on or OFF to turn the lamp off. b. Accept the selected option. Lamp Status During Power 1. Highlight State/Power On. On 2. To change the lamp status during power on, press . a.
Operation Display Settings From the Main Menu, highlight Display Settings and press . Overturn Display 1. Highlight Display Inverse. 2. To overturn the display, press . a. Select YES to turn the LCD around or NO to keep the normal LCD view. b. Accept the selected option. LCD Backlight Off 1. Highlight Backlight Auto Off. 2. To configure the LCD backlight, press . a. Select YES to automatically turn the LCD backlight off after 1 minute or NO to keep the LCD backlight always on. b.
Operation Reset Functions From the Main Menu, highlight Reset and press . You can leave this sub-menu at any time by pressing
Operation Special Functions From the Main Menu, highlight Special Functions and press . Fixture Maintenance Timers 1. Highlight Fixture Maintenance and press (the current maintenance interval and remaining time will show). 2. To change the maintenance interval timer, highlight Interval and press . a. Select the new interval 10–300 h (in hours). b. Accept the new value. 3. To reset the counter for the remaining time, highlight Remain Time and press . a.
Operation Gobo • Select Gobo and press . a. Select the new value (-128–127). b. Accept the new value. R-Gobo • Select R-Gobo and press . a. Select the new value (-128–127). b. Accept the new value. Gobo 2 • Select Gobo 2 and press . a. Select the new value (-128–127). b. Accept the new value. Iris • Select Iris and press . a. Select the new value (000–255). b. Accept the new value. Prism • Select Prism and press . a. Select the new value (000–255). b.
Operation DMX Values Mode1 (21) Channel Function Value Percent/Setting 1 Pan 000 ó 255 0–100% 2 3 4 5 6 Fine Pan Tilt Fine Tilt Pan/Tilt Speed Dimmer 7 Shutter 8 Color Wheel 000 ó 255 000 ó 255 000 ó 255 000 ó 255 000 ó 255 000 ó 007 008 ó 015 016 ó 131 132 ó 167 168 ó 203 204 ó 239 240 ó 247 248 ó 255 000 ó 007 008 ó 015 016 ó 023 024 ó 031 032 ó 039 040 ó 047 048 ó 055 056 ó 063 064 ó 127 128 ó 189 190 ó 193 194 ó 255 0–100% 0–100% 0–100% Fast to slow 0–100% No function Open Slow to fast (
Operation DMX Values (Cont.) Mode1 (21) (cont.
Operation DMX Values (cont.) Mode1 (21) (cont.) Channel 21 Function Control Legend™ 330SR Spot User Manual Rev.
Operation DMX Values (cont.
Operation DMX Values (cont.) Mode2 (27) (cont.) Channel Function 14 Gobo Wheel 1 15 Gobo Wheel 1 Rotate 16 Gobo Wheel 2 17 18 Focus Zoom 19 Prism Wheel 20 Prism Rotation 21 Iris Legend™ 330SR Spot User Manual Rev.
Operation DMX Values (cont.) Mode2 (27) (cont.
Operation DMX Values (cont.) Mode2 (27) (cont.) Channel Function 26 Color Macro 27 Control Legend™ 330SR Spot User Manual Rev.
Technical Information 5. TECHNICAL INFORMATION Product Maintenance To maintain optimum performance and minimize wear, you should clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency. As a rule, clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear. To clean your product: 1. Unplug the product from power. 2.
Technical Information Error Messages Message Cause(s) Action(s) Lamp Startup Fail The lamp has not started after being struck • Check lamp • Check lamp socket and wiring • Send product for repair Temperature Sense Error No communication with temperature sensor • Check sensor wiring • Check sensor integrity • Send product for repair Lamp Too Hot Low Power Ambient temperature higher than 104 °C; lamp in low power for safety • Check fans • Check fan wiring • Clean vents Lamp Too Hot Power Off Amb
Technical Information 6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 13.5 in (344 mm) 17.1 in (435 mm) 25.5 in (649 mm) 47 lb (21.3 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Light Source Gobo Dimensions Photo Optic Thermal DMX Ordering -30- Power Supply Type Range Voltage Selection Switching (internal) 100–240 VAC, 50/60 Hz Auto-ranging Parameter 120 VAC, 60 Hz 230 VAC, 50 Hz Consumption Current Fuse 514 W 4.
Technical Information Returns You must send the product prepaid, in the original box, and with the original packing and accessories. CHAUVET® will not issue call tags. Call CHAUVET® and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return. Clearly label the package with an RMA number. CHAUVET® will refuse any product returned without an RMA number.