Error Messages
Message Cause(s) Action(s)
Lamp Startup Fail
The lamp has not started after being
struck
• Check lamp
• Check lamp socket and wiring
• Send product for repair
Temperature Sense Error
No communication with temperature
sensor
• Check sensor wiring
• Check sensor integrity
• Send product for repair
Lamp Too Hot Low Power
Ambient temperature higher than
104 °C; lamp in low power for safety
• Check fans
• Check fan wiring
• Clean vents
Lamp Too Hot Power Off
Ambient temperature higher than
110 °C; lamp off for safety
• Check fans
• Check fan wiring
• Clean vents
Maintenance Fixture
Fixture Maintenance timer expired
• Proceed with maintenance and reset timer
Memory Initial Fail
Memory chip error
• Send product for repair
CPU-B Error
CPU-C Error
CPU-D Error
No communication with auxiliary CPU
• Check sensor’s wiring and position
• Send product for repair
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Moving head failed to go to home
position after power up or fixture reset
• Check moving head’s free movement
• Check sensors’ wiring and position
• Send product for repair
Dimmer Reset Fail
Color Reset Fail
Gobo Reset Fail
Focus Reset Fail
Zoom Reset Fail
Frost Reset Fail
Indicated moving part failed to go to
its home position after power up or
fixture reset
• Check part’s free movement and integrity
• Check sensors’ wiring and position
• Send product for repair