Derby X™ Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle USER MANUAL 3000 N 29th Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.
TABLE OF CONTENTS 1. Before You Begin ........................................................................................................ 3 What is included ................................................................................................................ 3 Unpacking Instructions ...................................................................................................... 3 AC Power ..................................................................................................
1. BEFORE YOU BEGIN What is included ¾ ¾ ¾ ¾ 1 x Derby X™ Power Cord Warranty Card User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials.
Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product. • • • • • • • • • • • • • • Caution! Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
2.
3. SETUP Fuse Replacement Disconnect the power cord before replacing a fuse and always replace with the same type fuse. With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. The fuse is located Insert the fuse holder back in its place inside this and reconnect power. compartment. Remove using a flat head screwdriver.
CABLE CONNECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 1 3 2 DMX connector configuration COMMON INPUT 1 3 2 CAUTION 1 3 2 DMX + DMX - Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the OUTPUT Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator. Do not allow contact between the common and the fixture’s chassis ground.
Master/Slave Fixture Linking 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
Stacking The Derby X™ may be “stacked” by using multiple fixtures and the optional bracket (XBRACKET). This bracket may be ordered from CHAUVET. The bracket kit will ship with 2pcs bracket (as shown below) and will include 4 screws for attaching it to the bottom of the fixture. • • Note: When you are installing this bracket, you must use the washers and bracket tightening knob to secure one fixture to another. Note: You must only stack a maximum of 4 fixtures.
4. OPERATING INSTRUCTIONS Operation Stand-Alone Mode (Sound-Active): This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode. 1) Set all dipswitches position to the Off position. Mode Sound Active Dipswitches 10 = Off 2) The unit will react to the low frequencies of music via the internal microphone in Sound Active mode. 3) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in Sound-Active mode.
DMX Channel Values Channel Value 1 2 3 4 5 6 000 Ù 010 011 Ù 045 046 Ù 080 081 Ù 115 116 Ù 150 151 Ù 185 186 Ù 220 221 Ù 255 7 000 Ù 010 011 Ù 255 8 000 Ù 010 011 Ù 024 025 Ù 038 039 Ù 052 053 Ù 066 067 Ù 080 081 Ù 094 095 Ù 108 109 Ù 122 123 Ù 136 137 Ù 150 151 Ù 164 165 Ù 178 179 Ù 192 193 Ù 206 207 Ù 220 221 Ù 250 251 Ù 255 Derby X™ User Manual Function Cluster Control No Function Red Green Blue Red/Green Red/Blue Green/Blue Red/Green/Blue Strobe No Function Strobe 0%~100% Auto Speed No Function Au
SETTING THE STARTING ADDRESS This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that uses 6 DMX channels and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105.
DMX QUICK REFERENCE CHART DMX Address Quick Reference Chart Dip Switch Position DMX DIP #9 SWITCH SET 0=OFF #8 1=ON #7 X=OFF or ON #6 #1 #2 #3 #4 #5 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 1 1 0 0 0 0 0 1 0 0 1 0 1 0 0 0 1 1 0 0 1 1 1 0 0 0 0 0 1 0 1 0 0 1 0 0 1 0 1 0 1 1 0 1 0 0 0 1 1 0 1 0 1 1 0 0 1 1 1 0 1 1 1 1 0 0 0 0 0 1 1 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 0 1 0 1 1 0 1 0 1 0 1 1 0 1 1 1 1 0 1 0 0 0 1 1 1 0 0 1 1 0 1 0 1 1 1 1 0 1 1 0 0 1 1 1 1 0 1 1 1 0 1 1 1 1 1 1 1 1 1 Dip Switch Position Derby X™ User Manual
Blow-out Diagram 3 6 8 1 2 4 7 5 1 2 3 4 5 6 7 8 Description Part Number Master PCB Electronic Transformer Case cover LED PCB Front Lens Bracket knob Power output Power input P172‐DERBYX P140‐DERBYX P111‐DERBYX P222‐DERBYX P150‐DERBYX P111‐DERBYX P176‐PWERIN P176‐PWROUT Derby X™ User Manual 14 7/14/2008 1:27 PM
General Troubleshooting Symptom(s) 1 or more LED’s are not illuminating 1 or more LED’s are producing very low output Breaker/Fuse keeps blowing Device has no power Fixture is not responding to DMX Possible Solution(s) Clean the fixture regularly to avoid any such failure. This fixture is convection cooled, which means that if the surface is kept clean and free of debris, then proper cooling will be allowed to occur An LED may have failed, resulting in an open circuit.
Technical Support Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com 5. APPENDIX DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels.
General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power.
Notes ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ____________________________________________________________________
Technical Specifications WEIGHT & DIMENSIONS Length..................................................................................................... 11.9 in (302 mm) Width ......................................................................................................... 15 in (382 mm) Height ....................................................................................................... 7.4 in (187 mm) Weight .................................................................................
3000 N 29th Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.