User manual

Operation
-12- COLORado™ 1 Quad IP User Manual Rev. 1
Dimmer Curves
This setting determines how fast the output of the COLORado™ 1 Quad IP changes when
you modify the values of the Red, Green, Blue, White, and Dimmer faders.
This setting
provides four different options to simulate the dimming curve of an incandescent lighting
product.
1. Go to the SET main level.
2. Select DIM.
3. Select a dimmer curve (OFF, DIM1, DIM2, DIM3, or DIM4).
OFF:
The output is proportional (linear) to the Dimmer and RGBW channel
values.
DIM1~4:
The output follows the Dimmer and RGBW channel values based on the
corresponding dimmer curve, being DIM1 the fastest and DIM4 the slowest.
Control Panel
Lock
This setting enables you to activate or disable the control panel lock, which keeps non-
authorized personnel from changing the product’s settings.
1. Go to the KEY main level.
2. Select ON or OFF.
When the control panel lock is active, the product will prompt you to enter the
password after 30 seconds of control panel inactivity or after turning on the product.
After being prompted to enter the password:
Press <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>.
Program Upload
This option allows you to copy the custom programs of one COLORado™ 1 Quad IP onto
other COLORado™ 1 Quad IP by using the Master/Slave mode.
1. Configure and connect the products in a Master/Slave arrangement, where the master
product has the custom programs you want to transfer to the slave products.
2. From the master product, go to the SET main level.
3. Select UPLD.
4. When PASS shows, press <ENTER>.
5. Enter the master access password as shown in Control Panel Lock.
6. When SEND shows, press <ENTER> to start the upload.
7. Wait for the upload process to finish (the display will show END before continuing or
turning the products off.
The Master/Slave products will provide the status of the process by lighting up as
follows:
Yellow indicates that the upload process is running.
Green indicates that the upload process completed successfully.
Red indicates that the upload process failed due to an error. Recheck all cable
connections and restart the process. If the issue persists, contact CHAUVET®
Technical Support.
DO NOT upload the data from a COLORado™ 1 Quad IP to a different product. The
other product may become inoperative.