Hurricane™ 1100 F-1100 User Manual
TABLE OF CONTENTS 1. Before You Begin ........................................................................................................ 3 What Is Included .............................................................................................................................. 3 Unpacking Instructions .................................................................................................................... 3 Claims ........................................................................
1. BEFORE YOU BEGIN What Is Included 1 x Hurricane™ 1100 1 x FC-M Wired Manual Remote 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling.
Safety Instructions Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
2.
Product Dimensions 242 mm / 9.5 in 225 mm / 8.9 in 258 mm / 10.
3. SETUP AC Power To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
Mounting Orientation This fixture should only be mounted/used on a flat surface. This fixture may not be tilted. Rigging It is important never to obstruct the vents’ pathways. Mount the fixture using, a suitable “C” or “O” type clamp. When selecting installation location, take into consideration the fluid reservoir access and routine maintenance. Safety cables must always be used, utilizing the provided safety eye bolt.
4. OPERATING INSTRUCTIONS This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog machine to run off bursts with adjustable interval and duration settings. Manual Remote Operation (FC-M) (Standard) 1. Plug in the fog machine to power. 2. Plug in the M remote to the Manual Controller socket on the rear of the fog machine. 3. Press the single button located on the remote to trigger the fog output.
Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines, or many more if you run them simultaneously. See the below instructions on setting up your fogger to operate with the FC-W. 1. Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”. 2.
General Troubleshooting Symptom No Power No fog output Breaker/Fuse keeps blowing Low fog output Fog machine is not heating up Remote does not work Fluid indicator states no fog, but the container if full. Solution(s) Check mains power. Check external fuse. Check internal fuse. Check fluid level. Check remote. If using wireless, check batteries. If using wireless, check dipswitches on receiver. Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for further instruction.
5. APPENDIX General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power.
Returns Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
TECHNICAL SPECIFICATIONS WEIGHT & DIMENSIONS Length ...................................................................................................... 10.2 in (258 mm) Width .......................................................................................................... 9.5 in (242 mm) Height ......................................................................................................... 8.9 in (225 mm) Weight ...........................................................................