User Manual
TABLE OF CONTENTS 1. Before You Begin ...........................................................................................................3 What Is Included ......................................................................................................................... 3 Unpacking Instructions ................................................................................................................ 3 Claims ...............................................................................
1. BEFORE YOU BEGIN What Is Included Mini Kinta™ Power Cord • • • • Warranty Card Quick Reference Guide Unpacking Instructions Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition. Claims If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not CHAUVET®.
Product at a Glance Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Safety Notes Auto Programs Auto-ranging Power Supply Replaceable Fuse User-Serviceable Duty Cycle These notes include important information about the mounting, usage, and maintenance of this product; read before using the product. • • • • • • • • • • • • • • • • • • • • Page 4 of 15 Always connect the product to a grounded circuit to avoid the risk of electrocution.
2. INTRODUCTION Overview Safety Loop Microphone Sensitivity Adjustment Knob LED Display Indicator Lights Microphone Back Panel View Button Menu Power Out Fuse Holder Power In Mini Kinta™ User Manual (Rev.
Dimensions Page 6 of 15 Mini Kinta™ User Manual (Rev.
3. SETUP AC Power The Mini Kinta™ has an auto-ranging power supply and it can work with an input voltage range of 100~240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Power Linking The product provides power linking via the IEC outlet located in the back of the unit. 1st Product Power Linking Diagram 2nd Product rd 3 Product Other Products You can power link up to 26 Mini Kinta™ units on 120 VAC or up to 53 Mini Kinta™ units on 230 VAC.
Mounting Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. Orientation The Mini Kinta™ may be mounted in any position; however, make sure adequate ventilation is provided around the product. Rigging • Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
4. OPERATION Control Panel Operation To access the control panel functions, use the four buttons located underneath the display.
DMX Channel Modes, Assignments, and Values 3-CH Channel Configuration (Standalone) Function 1 Control/Operating Mode 2 Strobe 3 Motor Rotation Value 000 005 006 020 021 035 036 050 051 065 066 080 081 095 096 110 111 125 126 140 141 155 156 170 171 185 186 200 201 215 216 230 231 255 000 005 006 255 000 001 127 128 255 Setting No function Red Green Blue White Red/Green Red/Blue Red/White Green/Blue Green/White Blue/White Red/Green/Blue Red/Green/White Gre
Master/Slave Mode The Master/Slave mode allows a single Mini Kinta™ unit (the “master”) to control the actions of one or more Mini Kinta™ units (the “slaves”) without the need of a DMX controller. The master unit will be set to operate in auto/sound mode, while the slave units will be set to operate in slave mode. Once set and connected, the slave units will operate in unison with the master unit. Configure the units as indicated below. Slave units: 1.
5. TECHNICAL INFORMATION Product Maintenance Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and mechanical wear. To maintain optimum performance and minimize wear, clean the product at least twice a month. However, usage and environmental conditions contribute to increased cleaning frequency. To clean the product, follow the instructions below: • Unplug the product from power.
6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 7.5 in (190 mm) 10.1 in (258 mm) 7.2 in (182 mm) 4.4 lbs (2.0 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Light Source Photo Optic Thermal DMX Ordering Page 14 of 15 Power Supply Type Range Voltage Selection Switching (internal) 100~240 V, 50/60 Hz Auto-ranging Parameter 120 V, 60 Hz 230 V, 50 Hz Consumption 19 W 25 W Operating/Inrush current 0.2 A/0.2 A 0.1 A/0.
To return a product or request support: • • • In the U.S., contact CHAUVET® World Headquarters. In the UK or Ireland, contact CHAUVET® Europe Ltd. In any other country, DO NOT contact CHAUVET®. Contact your distributor. See www.chauvetlighting.com for distributors outside the U.S., United Kingdom, or Ireland. If you live outside the U.S., United Kingdom, or Ireland, contact your distributor of record and follow their instructions on how to return CHAUVET® products to them.