User manual
Page 12 of 20 Obsession™ LED 2.0 User Manual (Rev. 03)
Master/Slave
Mode
This mode allows a single Obsession™ LED 2.0 unit (the “master”) to control the actions
of one or more Obsession™ LED 2.0 units (the “slaves”) without the need of a DMX
controller. The master unit will be set to operate in either Automatic or Sound Active
mode, while the slave units will be set to operate in Slave Mode. Once set and
connected, the slave units will operate in unison with the master unit.
Configure the units as indicated below.
Slave units:
1. Press <MENU> repeatedly until 512 shows on the display.
2. Press <ENTER> to accept.
3. Set the DMX address to “d001”, as previously explained.
4. Connect the DMX input of the first slave unit to the DMX output of the master unit.
5. Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
6. Finish setting and connecting all the slave units.
Master unit:
1. Set the master unit to operate in either Automatic or Sound mode.
2. Make the master unit the first unit in the DMX daisy chain.
Configure all the slave units before connecting the master unit to the DMX
daisy chain.
Never connect a DMX controller to a DMX string configured for Master/Slave
operation because it may interfere with the signals from the master unit.
Do not connect more than 31 slave units to the master unit.
DMX Channel Assignments and Values
3-CH
Channel Function Value Setting
1 Dimmer 000 255 0~100%
2 Strobe
000 009 No function
010 255 Slow to fast
3 Control
000 063 Gobos rotating, mirror dish rotating
064 127 Gobos static, mirror dish rotating
128 191 Gobos rotating, mirror dish static
192 255 Gobos static, mirror dish static