User Manual
TABLE OF CONTENTS 1. Before you Begin ............................................................................ 3 What is Included........................................................................................ 3 Unpacking Instructions .............................................................................. 3 Text Conventions ...................................................................................... 3 Icons ........................................................................
1. BEFORE YOU BEGIN What is Included 1 x Orb™ 1 x Power Cord 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving this product, carefully unpack it and check the container in which you received it. Make sure that you have received all the parts indicated above and that they are all in good condition.
Product at a Glance Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave Auto Programs Auto-ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle Safety Notes Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. Page 4 of 17 Keep this User Manual for future consultation. If you sell this product to another user, be sure that they also receive this document.
2. INTRODUCTION Hanging bracket Bracket knob Power out Power in Fuseholder DMX in DMX out Microphone Microphone Adjustment Safety DIP switches Orb™ User Manual (Rev.
3. SETUP AC Power This product has an auto-ranging power supply and it can work with an input voltage range of 100~240 VAC, 50/60 Hz. To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating indicates its average current draw under normal conditions.
Mounting Orientation The Orb™ may be mounted in any position, provided there is adequate room for ventilation around it. Rigging Be sure that the structure onto which you are mounting this product can support its weight. Please see the “Technical Specifications” section of this manual for weight information. Make sure to mount the fixture securely to a rigging point, whether an elevated platform or a truss.
4. OPERATION Control Panel Operation Configuration (DMX) Set this product in DMX mode to control it with a DMX controller. 1) Connect this product to a suitable power outlet. 2) Turn this product on. 3) Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product. Starting Address When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses.
Configuration (Standalone Modes) Set this product in one of the standalone modes to control it without a DMX controller. 1) Connect this product to a suitable power outlet. 2) Turn this product on. Sound Active Mode To enable the Sound Active mode, do the following: 1) Set DIP switch [9] to the ON position. 2) Turn the music on and adjust the microphone sensitivity knob until the fixture starts reacting to the beat of the music.
Master/Slave Mode This mode allows a single Orb™ unit (the “master”) to control the actions of one or more Orb™ units (the “slaves”) without the need of a DMX controller. The master unit will be set to operate in either Automatic or Sound Active mode, while the slave units will be set to operate in Slave Mode. Once set and connected, the slave units will operate in unison with the master unit. Configure the units as indicated below. Slave units: 1) Set DIP switch [10] to the ON position.
5. TECHNICAL INFORMATION General Maintenance Dust build up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, you should clean your lighting fixtures at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
General Troubleshooting Symptom Circuit breaker or fuse keeps blowing Product does not power up Possible Cause Possible Action Excessive load on the circuit Make sure that the total load does not exceed 80% of the breaker or fuse nominal current Short circuit along the power lines Check the power lines and power cords No energy on power outlet Check power outlet Change to another outlet Loose or damaged power cord Check the power cord Blown fuse Replace blown fu
Returns Procedure The user must send the merchandise prepaid, in the original box, and with its original packing and accessories. CHAUVET® will not issue call tags. Call CHAUVET® and request a Return Merchandise Authorization (RMA) number before shipping the fixture. Be prepared to provide the model number, serial number, and a brief description of the cause for the return. The user must clearly label the package with a Return Merchandise Authorization (RMA) number.
DMX Primer The USITT DMX512-A data transmission protocol (DMX, from now on) is based on the EIA-485 standard and it has 512 channels (001 to 512). This system requires a controller (DMX controller), one or more DMX compatible fixtures, and a DMX circuit (also known as “DMX universe”) to link the fixtures to the controller. Depending on their complexity and features, DMX compatible fixtures may require from one to more than 30 DMX channels to operate.
DMX Cabling The DMX protocol requires using special data cables to accommodate for the high speed digital signals it uses. Despite their apparent similarities, data cables are electrically different from standard microphone cables because they can carry high frequency digital signals and have better protection against electromagnetic interference. You can purchase CHAUVET® certified DMX cables directly from a dealer/distributor or make your own DMX cable.
DIP Switch Reference Guide You can use the table below to set your fixture’s DIP switches. Imagine that you want to find the DIP switch settings for DMX address 328: 1) Find 328 among the addresses from the table and point at it with your finger. 2) Move your finger to the left and you will find the settings for DIP Switches 1 to 5. DIP Switches 1, 2, 3, and 5 are Off (0), while DIP Switch 4 is On (1). 3) Go back and point at the 328 address.
6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 17.7 in (450 mm) 12 in (305 mm) 12 in (305 mm) 6.7 lbs (3.1 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Power Supply Type Range Voltage Selection Switching (internal) 100~240 V, 50/60 Hz Auto-ranging Parameter 120 V, 60 Hz 230 V, 50 Hz Consumption 34 W (0.29 A) 28 W (0.