User Manual
Edition Notes Edition Notes The Rogue™ RH1 Hybrid User Manual Rev. 2 covers the description, safety precautions, installation, programming, operation, and maintenance of the Rogue™ RH1 Hybrid. Chauvet released this edition of the Rogue™ RH1 Hybrid User Manual in April 2015. Trademarks CHAUVET® is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET® or Copyright Notice Manual Use Chauvet).
Table of Contents Table of Contents 1. Before You Begin ...................................................................................................................................... 1 What Is Included ........................................................................................................................................................... 1 Claims ........................................................................................................................................
Table of Contents Tilt Angle .................................................................................................................................................................................... 18 Pan and Tilt Movement BlackOut ............................................................................................................................................... 18 Color Movement BlackOut .................................................................................................
Before You Begin 1. BEFORE YOU BEGIN What Is Included Claims Manual Conventions • Rogue™ RH1 Hybrid • Neutrik® powerCON® power cord • 2 Omega brackets with mounting hardware • Warranty Card • Quick Reference Guide Carefully unpack the product immediately and check the box to make sure all the parts are in the package and are in good condition.
Before You Begin Product At A Glance Use on Dimmer Outdoor Use Master/Slave DMX Safety Notes x x x P Auto Programs Auto-Ranging Power Supply Replaceable Fuse User-Serviceable x P P x Read all the following Safety Notes before working with this product. These notes include important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts.
Introduction 2. INTRODUCTION Description The Rogue™ RH1 Hybrid is a compact, electronic, moving yoke beam product equipped with a 330 watt X8 lamp that delivers an ultra-intense output of 111,000 lux@ 15m with tight beam angles of 1-4.5° in Beam Mode and 5-19° in Spot Mode. This hybrid beam and spot includes an optical system with 8-facet and 6-facet prism sets that are completely layerable and controllable.
Introduction Overview DMX Out Pan Lock DMX In Control Panel Mounting Plate Front View Power In Fuse Rear View Power Switch ¼-turn Head Access Screws Tilt Lock Handle Top View -4- Side View Rogue™ RH1 Hybrid User Manual Rev.
Introduction Dimensions 14.63 in 371 mm 9.54 in 242 mm 16.11 in 409 mm 13.58 in 345 mm 20.40 in 518mm 12.89 in 327 mm 4.53 in 115 mm 14.63 in 371 mm 9.54 in 242 mm 8.83 in 224 mm 25.11 in 638 mm 13.58 in 345 mm 4.53 in 115 mm Rogue™ RH1 Hybrid User Manual Rev.
Setup 3. SETUP AC Power Each Rogue™ RH1 Hybrid has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Rogue™ RH1 Hybrid, refer to the label affixed to the product. You can also refer to the Technical Specifications chart in this manual. The listed current rating indicates the maximum current draw during normal operation. For more information, you may download Sizing Circuit Breakers from the Chauvet website: www.
Setup Gobo Wheel The Rogue™ RH1 Hybrid includes two gobo wheels: 13 fixed gobos plus open on wheel 1 and 9 rotating gobos plus open on wheel 2. The diagram shows the gobo number on the wheel, as numbered in the DMX Values tables. Open 1 2 3 Spot Aperture 13 12 Gobo Wheel 1 4 11 5 10 6 9 8 7 The gobos on gobo wheel 2 are not removable. 15.6 mm 1 9 14.44 mm 8 2 7 3 Gobo Wheel 2 6 5 4 Gobo Dimensions Gobo Wheel 2 Rogue™ RH1 Hybrid User Manual Rev.
Setup Gobo The gobos in the Rogue™ RH1 Hybrid gobo wheel 2 are removable from their gobo holders. Replacement This operation is quite simple, although it requires the technician to be careful and to follow the recommended procedure. • • • Procedure 1. 2. 3. 4. 5. 6. 7. 8. Make sure to disconnect the product’s power cord before replacing a gobo Always replace a gobo with a gobo of the same dimensions.
Setup Color Wheel The Rogue™ RH1 Hybrid includes one color wheel with 13 fixed colors plus open (white), as indicated below. The diagram shows the color number on the wheel, as numbered in the DMX Values tables. 13 UV 12 1 Open (White) Red 2 5600k Orange 11 Cyan 3200k 10 3 Light Green 4 Blue Light Yellow Dark Yellow 9 Dark Blue Green 5 Magenta 6 8 7 Rogue™ RH1 Hybrid User Manual Rev.
Setup Lamp The Rogue™ RH1 Hybrid is equipped with procedure below to safely change the lamp. Replacement an Osram Sirius 330W X8 lamp. Follow the Disconnect the product from power before opening. Procedure 1. Turn the product off and disconnect it from power. Wait at least 15 minutes for the lamp to cool down. 2. Remove back cover using the 2 Phillips-head ¼-turn screws on the rear panel of the head. 3.
Setup Procedure 4. Take note as to the orientation of the lamp. Vent holes on the front of the lamp should align horizontally with the air vents on the lamp frame. This is extremely important for lamp cooling (Cont.) when replacing the lamp. (see step 5 for location of vents on the lamp) Using the lamp base, push the lamp down against the spring clips and then roll the lamp out the top. Lamp Cooling Vents 5. Remove the 2 wires connected to the lamp by the spade connectors. Lamp Vents Spade Connectors 6.
Setup Mounting Orientation Before mounting this product, read and follow the Safety Notes. For our CHAUVET® Professional line of mounting clamps, go to http://trusst.com/products/. Always mount this product in a safe position and make sure there is adequate room for ventilation, configuration, and maintenance. Rigging Chauvet recommends using the following general guidelines when mounting this product.
Operation 4. OPERATION Control Panel Description Button Function
Operation Menu Map Main Level Programming Levels Address 001–512 Description Sets the DMX starting address 20CH 25CH DMX Auto Test Pan Pan Fine Tilt Tilt Fine Selects the DMX mode Runs the product’s test sequence P/T Speed Dimmer Dimmer Fine Shutter Color Gobo2 Run Mode Manual Test Gobo Gobo Rot Focus Focus Fine Zoom Zoom Fine 000–255 Allows manual control of all settings from the control panel Prism1 Prism1 Rot Prism2 Prism2 Rot Frost1 Frost2 P/T Macro P/T Ma.
Operation Menu Map (Cont.) Main Level Programming Levels Pan Reverse Tilt Reverse Screen Reverse Pan Angle Tilt Angle BL.O.P/T Move BL.O.ColorMove Setup BL.O.
Operation Menu Map (Cont.) Main Level Programming Levels Maintenance Timer Interval 10–250 Remaining Time NO Pan/Tilt Shutter/ Prism Setup (Cont.
Operation Address Set the DMX Address Run Mode DMX Personality This programming level sets the DMX starting address. • Starting from the Main Level screen, select Address, press . In this mode, each product will respond to a unique starting address from the DMX controller. All products with the same starting address will respond in unison. This option sets the products DMX address. • Change the starting address (001–512), press .
Operation Setup Pan Reverse Tilt Reverse Screen Reverse Pan Angle Tilt Angle Pan and Tilt Movement BlackOut Color Movement BlackOut Gobo Movement BlackOut -18- This programming level controls the product’s head movement, lamp adjustments, and maintenance timer. • Starting from the Main Level screen, select Setup, press . Reverses the operation of the pan attribute. 1. Highlight Pan Reverse, press . 2. Select YES or NO, press . Reverses the operation of the tilt attribute. 1.
Operation Lamp Settings This programming level allows the user to change a range of options that control the action of the lamp. • Starting from the Setup screen level, select Lamp Settings, press . Turning the Lamp This option turns the lamp on and off. On/Off 1. Highlight On/Off, press . 2. Select ON or OFF, press .
Operation Maintenance This programming level allows the user to change a range of options that control the action of Timer the maintenance timer. • Starting from the Setup screen level, select Maintenance Timer, press . Maintenance Timer This option defines the amount of time (hours) that the maintenance timer will count down to. Interval 1. Highlight Interval, press . 2. Select YES or NO, press . Maintenance Timer This option resets the maintenance timer. Reset 1.
Operation System Information Offset Mode Pan Tilt Dimmer Gobo Color Prism Rotating Prism Zoom Focus Frost This programming level shows standard information regarding the product’s operating status. • Starting from the Main Level screen, select Sys Info, press . • Ver: The current software version is displayed on the screen. • Running Mode: The current Running mode is displayed on the screen. • DMX Address: The current DMX address is displayed on the screen.
Operation DMX Values 25CH Channel -22- Function Value Percent/Setting 1 Pan 000ó255 0–100% 2 3 4 5 6 7 Fine Pan Tilt Fine Tilt Pan/Tilt Speed Dimmer Fine Dimmer 8 Shutter 9 Color Wheel 000ó255 000ó255 000ó255 000ó255 000ó255 000ó255 000ó007 008ó015 016ó131 132ó167 168ó203 204ó239 240ó247 248ó255 000ó003 004ó007 008ó011 012ó015 016ó019 020ó023 024ó027 028ó031 032ó035 036ó039 040ó043 044ó047 048ó051 052ó059 060ó187 188ó219 220ó223 224ó255 Fine control (16-bit) 0–100% Fine control (16-bit) 0–10
Operation DMX Values (Cont.) 25CH Channel (Cont.) 10 Function Gobo Wheel 1 Rogue™ RH1 Hybrid User Manual Rev. 2 Value 000ó003 004ó006 007ó009 010ó012 013ó015 016ó018 019ó021 022ó024 025ó027 028ó030 031ó033 034ó036 037ó039 040ó042 043ó059 060ó063 064ó067 068ó071 072ó075 076ó079 080ó083 084ó087 088ó091 092ó095 096ó099 100ó103 104ó107 108ó111 112ó127 128ó189 190ó193 194ó255 Percent/Setting Open (See note in Ch.
Operation DMX Values (Cont.) 25CH Channel (Cont.) Function For open aperture to engage, Gobo Wheel 1 must be set in the open position.
Operation DMX Values (Cont.) 25CH Channel (Cont.) 23 Function Movement Macros Rogue™ RH1 Hybrid User Manual Rev.
Operation DMX Values (Cont.) 25CH Channel Function (Cont.
Operation DMX Values (Cont.) 20CH Channel Function Value Percent/Setting 1 Pan 000ó255 0–100% 2 3 4 5 6 Fine Pan Tilt Fine Tilt Pan/Tilt Speed Dimmer 7 Shutter 8 Color Wheel 000ó255 000ó255 000ó255 000ó255 000ó255 000ó007 008ó015 016ó131 132ó167 168ó203 204ó239 240ó247 248ó255 000ó003 004ó007 008ó011 012ó015 016ó019 020ó023 024ó027 028ó031 032ó035 036ó039 040ó043 044ó047 048ó051 052ó059 060ó187 188ó219 220ó223 224ó255 Rogue™ RH1 Hybrid User Manual Rev.
Operation DMX Values (Cont.) 20CH Channel (Cont.) 9 -28- Function Gobo Wheel 1 Value 000ó003 004ó006 007ó009 010ó012 013ó015 016ó018 019ó021 022ó024 025ó027 028ó030 031ó033 034ó036 037ó039 040ó042 043ó059 060ó063 064ó067 068ó071 072ó075 076ó079 080ó083 084ó087 088ó091 092ó095 096ó099 100ó103 104ó107 108ó111 112ó127 128ó189 190ó193 194ó255 Percent/Setting Open (See note in Ch.
Operation DMX Values (Cont.) 20CH Channel (Cont.) Function For open aperture to engage, Gobo Wheel 1 must be set in the open position. (Value 000-003) 10 Gobo Wheel 2 11 Gobo Wheel 2 Rotate 12 13 Focus Zoom 14 Prism 1 15 Prism 1 Rotate 16 Prism 2 17 Prism 2 Rotate 18 19 Frost Beam Defraction Rogue™ RH1 Hybrid User Manual Rev.
Operation DMX Values (Cont.) 20CH Channel (Cont.
Technical Information 5. TECHNICAL INFORMATION Product Maintenance To maintain optimum performance and minimize wear, you should clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency. As a rule, clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear. To clean your product: 1. Unplug the product from power. 2.
Technical Specifications 6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 16.1 in (409 mm) 12.9 in (327 mm) 25.8 in (638 mm) 55.2 lb (25.1 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Light Source Photometrics Thermal DMX Ordering -32- Power Supply Type Range Voltage Selection Switching (internal) 100–240 VAC, 50/60 Hz Auto-ranging Parameter 120 VAC, 60 Hz 230 VAC, 50 Hz Consumption Current Fuse 548 W 4.
Technical Specifications Returns You must send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags. Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return. Clearly label the package with an RMA number. Chauvet will refuse any product returned without an RMA number.
User Manual CONTACT US WORLD HEADQUARTERS - Chauvet General Information Technical Support Address: 5200 NW 108th Avenue Voice: (954) 577-4455 (Press 4) Sunrise, FL 33351 Fax: (954) 756-8015 Voice: (954) 577-4455 Email: tech@chauvetlighting.com Fax: (954) 929-5560 World Wide Web www.chauvetlighting.com Toll free:(800) 762-1084 UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd. General Information Technical Support Address: Unit 1C Email: uktech@chauvetlighting.