LRG-55 Scorpion™ 55 RG USER MANUAL CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.
TABLE OF CONTENT BEFORE YOU BEGIN.................................................................................................................................... 3 WHAT IS INCLUDED......................................................................................................................................... 3 UNPACKING INSTRUCTIONS ............................................................................................................................. 3 AC POWER ............................
BEFORE YOU BEGIN What is included ¾ ¾ ¾ ¾ 1 x Scorpion™ 55 RG Warranty Card User Manual Power cord Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials.
Introduction Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance? • • • • • • • • • • • • • Caution! LRG-55 User Manual Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
INTRODUCTION You may notice that both the red and green beams coming out of the projector are larger than the 4.95mW projectors. There is a very distinct reason for this. Unlike 4.95mW projectors the output of the CHAUVET laser projectors with Fatbeam™ technology inside outputs <20mW for each beam. Normally outputs greater than 4.95mW require a variance from the FDA. This product has been designed to meet a special classification of ClassIIIR.
Product Overview DANGER: Laser Radiation emitted from this aperture. Before connecting the unit to AC power, make certain that the front aperture is pointed away from you or others.
AC Power Connection: The unit is supplied with a power plug appropriate to its voltage and destination. Should any other connections be required they must be carried out with the following configuration. Earth = Green/Yellow cable Neutral = Blue cable Live = Brown cable General Instructions Please read carefully and thoroughly the contents of this manual before operating the Laser system. These instructions contain important safety information regarding the use and maintenance of this system.
COMPLIANCE STATEMENT Your LRG-55 complies with FDA/CDRH 21CFR1040 and Laser Notice 50 as well as IEC 608251:2003. Due to a unique optic design, this product does not exceed output powers that exceed its classification and output levels government agencies have determined to be appropriate for the products function. Laser Safety and Compliance Information This product is manufactured to comply with the IEC 60825-1 and in accordance with U.S.
Proper Usage This unit has been designed to be hung. It is recommended that, for safety purposes, your lighting effect are properly mounted using a suitable hanging clamp and safety cable. CHAUVET offers a range of items, which are ideal for safe mounting. It is the responsibility of the manufacturer to provide useful instruction on the proper use of this product. According to FDA Regulations you should operate the product in the fashion illustrated below.
DMX Mode In this mode you will be able to control each individual trait of the fixture independently. The LRG-55 occupies 8 channels of DMX control. For detailed listing of the DMX channel values refer to the Appendix section. SETTING TH E STAR TING ADDRESS This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address.
Operation Stand-Alone Operation (Sound_Active, Auto Mode): This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode. 1) Set dipswitches position to Sound Active or Auto Mode. Mode Dipswitches Sound Active 10 = Off, 11 = Off, 12 = Off Auto Mode 10 = Off, 11 = Off, 12 = On 2) The unit will react to the low frequencies of music via the internal microphone in Sound Active mode, or the unit will auto change in Auto Mode.
Universal DMX Control (DMX Mode): This mode allows you to use a universal DMX-512 controller to control lasers operation and effects. 1) To control your fixture in DMX Mode use standard XLR DMX cable to daisy chain your units together via the XLR connector on the rear of the units. For long cable runs we suggest a terminator at the last fixture. Mode Dipswitches DMX mode 10 = On, 11 = Off, 12 = On 2) Assign a DMX address to the unit by following the dipswitch chart.
APPENDIX DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance.
DMX Quick Reference Chart DMX Address Quick Reference Chart Dip Switch Position DMX DIP SWITCH SET 0=OFF #9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1=ON #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 X=OFF or ON #6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 #1 #2 #3 #4 #5 0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417
DMX Channel Values Channel Value 1 000 Ù 010 011 Ù 120 121 Ù 250 251 Ù 255 Mode Laser off Dynamic Patterns Static Patterns Sound Active Mode 2 000 Ù 255 Pattern Selection Static Patterns – Dynamic Patterns 3 000 Ù 255 X Position Left > Right 4 000 Ù 255 Y Position Top > Bottom 5 000 Ù 255 Scan Speed Fast > Slow 6 000 Ù 255 Dynamic Pattern Speed Control Fast > Slow / See page 16 7 000 Ù 255 Static Pattern Size Control Small > Big / See page 17 8 000 Ù 100 101 Ù 200 201 Ù 255 Color G
Dynamic Patterns & DMX Values LRG-55 User Manual 16 11/14/2007/18:46
Static Patterns & DMX Values LRG-55 User Manual 17 11/14/2007/18:46
General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power.
Technical Specifications WEIGHT & DIMENSIONS Length......................................................................................................................... 256 mm (10.08 in) Width .......................................................................................................................... 270 mm (10.63 in) Height ........................................................................................................................... 130 mm (5.12 in) Weight ...................