3. SETUP
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
FUSE
Fuse Replacement
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
With a flat-head screwdriver, unscrew the fuse holder from its housing. Remove the damaged
fuse from its holder and replace with exact same type fuse. Screw the fuse holder back in its
place and reconnect power.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512
controller or to run synchronized shows on two or more fixtures set to a master/slave operating
mode. The combined number of channels required by all the fixtures on a serial data link
determines the number of fixtures the data link can support.
Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the
EIA-485 standard no more than 32 devices should be connected on one data link.
Connecting more than 32 fixtures on one serial data link without the use of a DMX
optically-isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified
DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create
your own cable please use data-grade cables that can carry a high quality signal and are less
prone to electromagnetic interference.
DMX DATA CABLE
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485
applications. Standard microphone cables cannot transmit DMX data reliably over long
distances. The cable will have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
CABLE CONNECTORS