AC Power
Each Xeno™ 2500 has an auto-ranging power supply that works with an input voltage
range of 208~230 VAC, 50/60 Hz.
To determine the power requirements for each
Xeno™ 2500, refer to the label affixed to the product. You can also refer to the
Technical
Specifications chart in this manual.
The listed current rating indicates the maximum current draw during normal operation.
For more information, download Sizing Circuit Breakers from the CHAUVET® website
:
www.chauvetpro.com.
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Xeno™ 2500 comes with a power input cord terminated on one end with a Neutri
powerCON® A connector that connects to the product. The other is bare-ended. U
se the
table below to wire the new plug.
Connection
Wire (Europe)
Screw Color
AC Live
Brown
Yellow or Brass
AC Neutral
Blue
Silver
AC Ground
Green/Yellow
Green
Resetting the Breaker
This product is equipped with a resettable 20A circuit breaker on the power input circuit.
If the breaker trips, all sections of this product will lose power. Refer to the following
instructions for resetting the breaker.
1. Remove the power cord from mains power.
2. Allow product to cool for 15 minutes.
3. After 15 minutes, you may attempt to reset the breaker by pressing the button with
your index finger.
4. Plug the product’s power cord into the power outlet and continue using as
recommended.
Disconnect this product from the power outlet before resetting the breaker.
If the breaker does not reset (the breaker button
will not remain inserted), contact