Technical specications
CO
2
measurement
Measuring principle Non-diffusive infrared (NDIR) technology
Type of sensor Double-beam infrared cell sensor
Measurement range 0 to 5,000 ppm
Uncertainty ± 50 ppm ± 3 % of value measured
Response time, 63 % < 200 seconds
Resolution 1 ppm
Temperature measurement
Type of sensor CMOS
measurement range -10 °C to +60 °C
Accuracy ± 0.5 °C
Resolution 0.1 °C
Humidity measurement
Type of sensor Capacitive
Measurement range 5 to 95 % RH
Accuracy ± 2 % RH
Resolution 0.1 % RH
Specications
Recording interval Customizable from 1 minute to 2 hours
Storage More than 1 million measurements
Buzzer Yes
Units °C or °F
Backlighting
Display Hold function
Min-Max
Yes
Automatic power-off Yes (in portable mode only)
General specications
Product operating range Temperature: -10 °C to +60 ° C – Humidity: 5 to 95 %RH
Dimensions / weight 125 x 65.5 x 32 mm / 190 g with batteries
Protection IP40
Compliance IEC 61010-1 for 50 V in Category II – IEC 61326-1 – Compliance with French decree no. 2012-14
Power supply
- Alkaline batteries: 2 x 1.5 V AA / LR6 or rechargeable battery
- Connection to mains possible with mains / micro USB adapter supplied as standard
Interfaces
2 communication modes possible:
- Bluetooth wireless communication
- USB link; the product is then recognized as a USB key for easy file transfer
Mounting
C.A 1510 casing equipped with a magnet, a wall-suspension system and a slot for hanging the product. A wall support for use with a padlock
(padlock not supplied) is available as an accessory, as is a desktop stand (supplied as standard with the C.A 1510W).
Functions of the Data Logger Transfer
software supplied as standard
Graphic representation or as table of values – Data export – Real-time mode
Report generation
Types of use
Point measurement
Monitoring
Quick measurement and display of the CO
2
, temperature and relative humidity values
Monitoring
1D mode: indication of CO
2
confinement
Visual (two-colour backlighting & pictograms) and/or audible indication of high
confinement when the CO
2
concentration is between 1,000 ppm and a 1,700ppm
threshold.
3D mode: indication of optimum comfort zone on the basis of the hygrothermal criteria
and the CO
2
concentration.
Energy-saving (ECO): for fixed use on battery power, the product performs
measurements every 10 minutes over a programmable time range for a battery life of
up to one year.
Logger
Triggering of programmed recording (P
_
REC)
The start date, recording rate and end date can be customized with the PC software
or the Android application. Possibility of locking the display in this mode (no values
displayed).
Manual triggering (M_REC)
Manual start and stop controls on the product.
Recording is performed at the rate of the mode currently selected.
Indoor air quality tester
Charcoal-grey C.A 1510 .........................P01651010
Delivered in a small-format metal case with:
• 2 x LR6 batteries
• USB mains adapter
• USB-micro USB cable 1.80 m long
• Quick start-up guide
• Mini-CD containing the Data Logger Transfer software
and the user’s guides (one file per language)
• Verification attestation
Indoor air quality tester
White C.A 1510 .......................................... P01651011
Delivered in a cardboard box with:
• 2 x LR6 batteries
• USB mains adapter
• USB-micro USB cable 1.80 m long
• Desktop stand
• Quick start-up guide
• Mini-CD containing the Data Logger Transfer software
and the user’s guides (one file per language)
• Verification attestation
To order
FRANCE
Chauvin Arnoux
190, rue Championnet
75876 PARIS Cedex 18
Tel: +33 1 44 85 44 38
Fax: +33 1 46 27 95 59
export@chauvin-arnoux.fr
www.chauvin-arnoux.fr
UNITED KINGDOM
Chauvin Arnoux Ltd
Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk
Dewsbury, West Yorkshire - WF12 7TH
Tel: +44 1924 460 494
Fax: +44 1924 455 328
info@chauvin-arnoux.co.uk
www.chauvin-arnoux.com
MIDDLE EAST
Chauvin Arnoux Middle East
P.O. BOX 60-154
1241 2020 JAL EL DIB - LEBANON
Tel: +961 1 890 425
Fax: +961 1 890 424
camie@chauvin-arnoux.com
www.chauvin-arnoux.com
906211422 - Ed. 2 - 01/2019 - Non contractual document.
ACCESSORIES AND REPLACEMENT PARTS
• In-situ calibration kit (fits into in the metal case) .....................P01651022
• Hard case
................................................................................P01298071
• Desktop stand
..........................................................................P01651021
• White Wall support
.................................................................. P01651020
• Black Wall support
...................................................................P01651024
• USB mains adapter
.................................................................. P01651023
• USB-Bluetooth adapter
............................................................P01102112