Brochure
906111628 - Ed. 3 - VS 07-2015 - Non-contractual document. Please conrm specications before ordering.
(1) Additional “Voltest
TM
” function to check the possible presence of voltage on resistance and audible continuity test - (2) Limited to 240 A max by the miniclamp MN 89
(3) In % of end of scale - (4) Degree of pollution 2 - (5) Electronic protection and HBC fuses for the current ranges with fuse test light - (6) For use up to 600 V max.
To order
Multimeters
C.A 5001 ……………………………………………P01196521E
C.A 5003 ……………………………………………P01196522E
C.A 5005 (supplied with miniclamp MN 89) ……P01196523E
Supplied with IEC 1010 safety leads with test probes, battery and user
manual.
C.A 5001 set with case …………………………… P01196521F
C.A 5003 set with case …………………………… P01196522F
C.A 5005 set with case …………………………… P01196523F
Accessories
Shoulder bag (240 x 230 x 70 mm) ………………………P01298033
Carrying holster (220 x 180 x 75 mm) ……………………P01298036
Carrying case (270 x 200 x 65 mm)
with precut foam insert:
for the C.A 5001 or C.A 5003 ………………………………P01298037
for the C.A 5005 and MN 89 ………………………………P01298037A
Numerous safety accessories. Documentation on request.
Specifications
C.A 5001
C.A 5003
(1)
C.A 5005
(1)
DC voltage 8 ranges: 100 mV /.. / 1,000 V
(6)
AC voltage 5 ranges: 10 V /.. / 1,000 V
(6)
Internal resistance 20 kΩ/V
Working frequency 10 Hz ...100 kHz depending on range
DC current 5 ranges: 50 µA /.. / 5 A 7 ranges: 50 µA /.. / 15 A 6 ranges: 50 µA /.. / 10 A
AC current
4 ranges: 5 mA /.. / 5 A 5 ranges: 1.5 mA /.. / 15 A
5 ranges: 3 A /.. / 300 A
(2)
Resistance 2 ranges: 10 kΩ and 1 MΩ
Audible continuity test R < 50 Ω
Scale in dB for V AC 0 ... +22 dB
Typical accuracy
(3)
1.5 % on V • 2.5 % on V
~
and A • 10 % on Ω
Power supply 1.5 V battery 9 V battery
Battery life 10,000 measurements of 15 s 10,000 measurements of 10 s
Electrical safety
(4)
IEC / EN 61010-1 Edition 2 • 600 V Cat III-2
Protection
(5)
HRC fuses: 0.5 A and 5 A HRC fuses: 1.6 A and 16 A HRC fuses: 1 A and 10 A
Degree of watertightness IP 40 IP 53
Environmental conditions -10 °C ... +55 °C and RH < 90 %
Dimensions / Weight 160 x 105 x 56 mm / 500 g
The holsterThe shoulder bagThe case
C.A 5000 series
Analogue multimeters
For information and ordering
FRANCE
Chauvin Arnoux
190, rue Championnet
75876 PARIS Cedex 18
Tel: +33 1 44 85 44 38
Fax: +33 1 46 27 95 59
export@chauvin-arnoux.fr
www.chauvin-arnoux.com
UNITED KINGDOM
Chauvin Arnoux Ltd
Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk
Dewsbury, West Yorkshire - WF12 7TH
Tel: +44 1924 460 494
Fax: +44 1924 455 328
export@chauvin-arnoux.fr
www.chauvin-arnoux.fr
MIDDLE EAST