Brochure

Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102D - Ed 1
4.09 (2/2)
C100 series
Current clamp for AC current
MECHANICAL SPECIFICATIONS
Operating temperature:
-10 °C .. +50 °C
Storage temperature:
-40 °C .. +70 °C
Infl uence of temperature:
0.15 % of output signal per
10 °K from -10 °C .. +40 °C
0.2 % of output signal per 10 °K
from +40 °C .. +50 °C
Relative humidity for operation:
From 0 .. 85 % from RH decreasing linearly above
35 °C
Infl uence of relative humidity:
<0.1 % of output signal from 10 .. 85 % from RH
Operating altitude:
0 to 2,000 m
Max. jaw opening:
53mm
Patented progressive opening system
Clamping capacity:
Cable: Ømax 52mm
Busbar: 1 busbar of 50 x 5mm or 4 busbars
of 30 x 5mm
Casing protection rating:
IP40 (IEC529)
Drop test:
1 m (IEC68-2-32)
Shock resistance:
100 g (IEC68-2-27)
Vibration resistance:
5/15Hz 1.5mm
15/25Hz 1mm
25/55Hz 0.25mm
(IEC68-2-6)
Self-extinguishing capability:
UL94 V0
Dimensions:
216 x 111 x 45mm
Weight:
550 g
Colours:
Dark grey case with red jaws
Output:
1.5 m two-wire lead with double or reinforced
insulation terminated by 2 elbowed male safety
plugs (4 mm)
SAFETY SPECIFICATIONS
Electrical safety:
Instrument with double insulation or reinforced
insulation between the primary the secondary and
the grippable part located under the guard as per
IEC1010-1 & IEC1010-2-032
- 600V category III, pollution degree 2
- 300V category IV, pollution degree 2
Electromagnetic compatibility (EMC):
EN50081-1: classB
EN50082-2:
- Electrostatic discharge: IEC1000-4-2
- Radiated field: IEC1000-4-3
- Fast transients: IEC1000-4-4
- Magnetic field at 50/60 Hz: IEC1000-4-8
(1) Conditions of reference: 23 °C ± 3 °K, 20 % to 75 % RH, signal sinus, frequency of 48Hz to 65Hz, distortion factor <1 %,
no DC components, external magnetic fi eld <40A/m, no AC magnetic fi eld, conductor centred for measurement,
load impedance: ≥10MΩ and 47 pF
(2) Out of reference domain
To order Reference
AC current clamp model C173 with operating manual P01120309
Accessory: AN1 artificial neutral box
(see capter 12)
Bag n°11
P01197201
P01100120
Current clamp for AC current
Model C173
(probe for leakage currents)