Current range:
1 AAC .. 300 AAC
1 AAC .. 600 AAC
1 AAC .. 1,200 AAC
Current transformation ratio
250:5
500:5
1000:5
Output signal:
20 mAAC / AAC (5 A for 250 A)
10 mAAC / AAC (5 A for 500 A)
5 mAAC / AAC (5 A for 1,000 A)
Accuracy and phase shift
(1)
:
250 A calibre
Primary current 1 A .. 5 A 5 A 12,5 A
(2)
50 A
(2)
250 A
(2)
300 A
(2)
Accuracy en % 10 % + 2 mA 10 % 5 % 2.5 % 2 % 2 %
Phase shift not specified not specified 10° 10° 10° 10°
500 A calibre
Primary current 1 A .. 10 A 10 A 25 A
(3)
100 A
(3)
500 A
(3)
600 A
(3)
Accuracy en % 6 % + 1 mA 6 % 3 % 2 % 1 % 1 %
Phase shift not specified 6° 4° 3° 2.5 ° 2.5 °
1,000 A calibre
Primary current 1 A .. 20 A 20 A 50 A
(4)
200 A
(4)
1,000 A
(4)
1,200 A
(4)
Accuracy en % 6 % + 0.5 mA 5 % 3 % 1.5 % 1 % 1 %
Phase shift not specified 5 ° 3° 1.5° 1° 1°
Bandwidth:
48Hz .. 1 kHz
Crest factor:
250 A calibre:
6 with current 750 A peak
500 A calibre:
6 with current 1,500 A peak
1,000 A calibre:
6 with current 3,000 A peak
Maximum currents:
1,200 A for frequencies 1 kHz for 30minutes max
(interval between measurements >15minutes)
Load impedance:
250 A calibre: 0.2 Ω
500 A calibre: 0.4 Ω
1,000 A calibre: 0.4 Ω
Impedance of connection leads:
40 mΩ
Maximum output voltage (secondary open):
Electronic protection circuit limiting voltage
to 30V peak max
Operating voltage:
600V
RMS
Common mode voltage:
600 V category III and pollution degree 2
Infl uence of adjacent conductor:
250 A calibre: 15 mA / A at 50 Hz
500 A calibre: 10 mA / A at 50 Hz
1,000 A calibre: 1 mA / A at 50 Hz
Infl uence of conductor position in jaws:
For frequencies 400 Hz
250 A calibre: 0.6 % of output signal
500 A calibre: 0.4 % of output signal
1,000 A calibre: 0.2 % of output signal
Load infl uence:
250 A calibre: from 25 mΩ to 0.2 Ω
<2 % on measurement
<4° on phase
500 A calibre: from 50 mΩ to 0.4 Ω
<1 % on measurement
<2° on phase
1,000 A calibre: from 50 mΩ to 0.4 Ω
<0.5 % on measurement
<0.5 ° on phase
Infl uence of frequency
(5):
250 A calibre:
<1 % of output signal from 65Hz .. 100 Hz
<5 % of output signal from 100 Hz .. 1 kHz
500 A calibre:
<1 % of output signal from 65Hz .. 1 kHz
1,000 A calibre:
<0.5 % of output signal from 65Hz .. 100 Hz
<1 % of output signal from 100 Hz .. 1 kHz
Infl uence of crest factor:
<1 % of output signal for crest factor 6 with
current:
750 A peak (calibre 250 A)
1,500 A peak (calibre 500 A)
3,000 A peak (1,000 A calibre)
Infl uence of DC current superimposed on rated
current:
<1 % of output signal for a current 30 A DC
Current
250 AAC 500 AAC 1,000 AAC
Ratio
250:5 500:5 1000:5
Output
20 mA / A 10 mA / A 5 mA / A
Current clamp for AC current