Brochure
Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102A - Ed 1
1.06 (4/4)
Current clamp for AC current
MINI 100 series
Model MINI 103
(1) Conditions of reference: 23 °C ± 3 °K, 20 °C to 75% RH, sinusoidal signal with frequency of 48 Hz at 65 Hz, distortion factor <1% with no DC component, external DC magnetic fi eld <40A/m, no external AC magnetic fi eld,
no external conductor with circulating current, conductor centred for measurement, measurement instrument load impedance ≥ 10 kΩ.
(2) With clamp closed.
CURVES AT 50 Hz
Typical linearity error
FREQUENCY RESPONSE
Typical linearity error
Typical phase shift
Typical phase shift
-1 %
-0,5 %
0 %
0,5 %
1 %
1,5 %
2 %
0,01 A 0,1 A 1 A 10 A 100 A 1000 A
Courant primaire
Erreur de mesure
Erreur (%) 50 Hz
Erreur (%) 400 Hz
0 %
0,1 %
0,2 %
0,3 %
0,4 %
0,5 %
0,6 %
0,7 %
0,8 %
0,9 %
1 %
1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz
Fréquence
Erreur
Erreur (%) 10A
Erreur (%) 20A
-0,5 °
0 °
0,5 °
1 °
1,5 °
2 °
2,5 °
3 °
3,5 °
0,01 A 0,1 A 1 A 10 A 100 A 1000 A
Courant primaire
Erreur de phase
Phase (°) 50 Hz
Phase (°) 400 Hz
-4 °
-3 °
-2 °
-1 °
0 °
1 °
2 °
3 °
4 °
1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz
fréquence
Phase
Phase (°) 10A
Phase (°) 20A
Frequency response: phase
Phase
Primary current
Frequency
Frequency response
Linearity
Primary current
Frequency
To order Reference
AC current clamp model MINI 103 with operating manual P01106103
Error
Error
Error
Error
Error Error