Brochure
Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102A - Ed 1
1.04 (1/1)
MINI series
Current clamp for AC current
Model MINI 05
•
Output:
Double-insulated cable 1.5 m long, terminated
by 2 insulated elbowed male banana connectors
Ø4mm
•
Bandwidth:
48 Hz .. 500 Hz
•
Clamping capacity:
Cable Ømax 10mm
ELECTRICAL SPECIFICATIONS
•
Maximum currents:
■
100 A calibre
I <150 A permanent from 48 Hz .. 500 Hz
■
10 A calibre
I <15 A permanent from 48 Hz .. 500 Hz
•
Infl uence of temperature:
≤0.2% per 10 °K
•
Infl uence of adjacent conductor:
≤2 mA / A at 50 Hz
•
Infl uence of conductor position in jaws:
≤0.1% at 50/60 Hz
•
Infl uence of frequency:
■
100 A calibre:
≤1% from 65 Hz to 500Hz
■
10 A calibre:
≤3% from 65 Hz to 500Hz
MECHANICAL SPECIFICATIONS
•
Operating temperature:
-10 °C to +50 °C
•
Storage temperature:
-40 °C to +80 °C
•
Relative humidity for operation:
From 0 to 85% RH with a linear decrease above
35°C
•
Operating altitude:
0 to 2,000 m
•
Casing protection rating (leakproofi ng):
IP40
(2)
(EN60529 Ed. 1992)
•
Drop test:
1.5 m (IEC68-2-32)
•
Shock resistance:
100 g / 6 ms / half-period (IEC68-2-27)
•
Vibration resistance
(3)
:
5-15 Hz (1.5 mm), 15-25 Hz (1 mm), 25-55 Hz
(0.25mm) (IEC68-2-6)
•
Self-extinguishing capability:
casing UL94 V2
•
Dimensions:
130 x 37 x 25mm
•
Weight:
Approx. 180 g
•
Colour:
Black casing
SAFETY SPECIFICATIONS
•
Electrical safety:
Instrument with double insulation or reinforced
insulation between the primary, the secondary and
the grippable part located under the guard as per
EN61010-1 Ed.2:2001,
EN61010-2-031 Ed.2002 &
EN61010-2-032 Ed.2003
- 600 V categoryIII, pollution degree 2
- 300 V category IV, pollution degree 2
•
Electromagnetic compatibility:
CE-certifi ed equipment compliant with standard
EN61326-1 (Ed. 97) + A1 (Ed.98) + A2 (Ed.01)
- Emission: stipulations for class B equipment
(domestic use).
- Immunity: stipulations for equipment used
intermittently on industrial sites.
(1) Conditions of reference: 23 °C ± 3 °K, 20 °C to 75% RH, sinusoidal signal with frequency of 48 Hz to 65 Hz, distortion factor <1%
with no DC component, external DC magnetic fi eld <40A/m, no external AC magnetic fi eld, no external conductor with circulating current,
conductor centred for measurement, measurement instrument load impedance ≥ 1 MΩ (10 A calibre) & ≥ 10 kΩ (100 A calibre).
(2) With clamp closed.
(3) Vibrations expressed inmm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.
Calibre
10 A AC 100 A AC
Sensitivity
1 mV / mA 1 mV / A
DESCRIPTION
Small and compact, the MINI 05 current clamp is the ideal complement for
any multimeter to measure AC currents in low-power tertiary or industrial
applications.
With its 2 calibres, it offers excellent resolution for measuring AC currents
from 5mA to 100 A.
MAIN SPECIFICATIONS
(1)
Calibre 10 A 100 A
Measurement range 5 mA .. 10 A 1 A .. 100 A
Accuracy of primary
current in%
≤ 3 % + 0.15 mA ≤ 2 % + 50 mA
Phase shift not specified
Output signal
1 mV AC/ mAAC
(10 V for 10 A)
1 mV AC / A AC
(100 mV for 100 A)
To order Reference
AC current clamp model MINI 05 with operating manual P01105105Z