Brochure
Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102A - Ed 1
1.06 (1/4)
Current clamp for AC current
MINI 100 series
•
Output:
Double-insulated cable 1.5 m long, terminated
by 2 insulated elbowed male banana connectors
Ø4mm
•
Bandwidth:
48 Hz .. 10 000 Hz
•
Clamping capacity:
Cable Ømax 16mm
ELECTRICAL SPECIFICATIONS
•
Load impedance:
≤ 100 Ω
•
Infl uence of load impedance:
See curves
•
Maximum currents:
350 A permanent at a frequency ≤ 1 kHz.
200 A permanent at a frequency ≤ 8 kHz
(limitation proportional to the reciprocal of the
frequency beyond that)
•
Infl uence of temperature:
≤ 0.2 % per 10 °K
•
Infl uence of adjacent conductor:
≤ 2 mA / A at 50 Hz
•
Infl uence of conductor position in jaws:
≤ 0.08 % at 50/60 Hz
•
Infl uence of frequency:
≤ 1 % typique
•
Maximum output voltage (secondary open):
≤ 30 V
MECHANICAL SPECIFICATIONS
•
Operating temperature:
-10 °C to +50 °C
•
Storage temperature:
-40 °C to +80°C
•
Relative humidity for operation:
From 0 to 85% RH with a linear decrease above
35°C
•
Operating altitude:
0 to 2,000 m
•
Casing protection rating (leakproofi ng):
IP20
(2)
(EN60529 Ed. 2001)
•
Drop test:
1 m (IEC 68-2-32)
•
Dimensions:
130.4 x 46 x 34mm
•
Weight:
approx. 250 g
•
Colour:
Black casing
SAFETY SPECIFICATIONS
•
Electrical safety:
Instrument with double insulation or
reinforced insulation between the primary,
the secondary and the grippable part located
under the guard as per EN 61010-1 Ed.2:2001,
EN 61010-2-031 Ed. 2002 & EN 61010-2-032
Ed.2003
- 600 V categoryIII, pollution degree 2
- 300 V category IV, pollution degree 2
•
Electromagnetic compatibility:
CE-certifi ed equipment compliant with standard
EN61326-1: 2006
- Emission: stipulations for class B equipment
(domestic use).
- Immunity: stipulations for equipment used
intermittently on industrial sites.
Calibre
200 A AC
Sensitivity
1 mA / A (1000 / 1)
DESCRIPTION
The MINI 102 current clamp, whose jaws are equipped with a high-
performance magnetic material and a double coil, offer excellent linearity
and improved performance.
If a current is present in the clamped conductor, the MINI 102 clamp is
protected against voltage surges when it is connected to the measuring
instrument.
MAIN SPECIFICATIONS
(1)
Calibre 200 A
Measurement range
50 mA .. 200 A (load 1 Ω)
50 mA .. 200 A (load 10 Ω)
50 mA .. 20 A (load 100 Ω)
Accuracy in%
≤ 1 % + 0.02 A (load 1 Ω)
≤ 1.5 % + 0.01 A (load 10 Ω)
≤ 4 % + 0.01 A (load 100 Ω)
Phase shift
≤ 3° (load 1 Ω)
≤ 6° (load 10 Ω)
≤ 12° (load 10 0Ω)
Output signal
1 mAAC / AAC (1000 / 1)
(200 mA for 200 A)
Model MINI 102