Instructions

21
9 - DIODE TEST
Connection and specifications: idem Resistances
Place the selector switch on the function
Analogue reading: voltage drop up to 2000 mV for the forward
direction of the component.
50 scale, reading coefficient x 100
Digital reading: for the forward direction of the component, voltage
drop up to 2000 mV.
Accuracy: digital 2 % rdg ± 2 counts and analogue 2.5 % full scale.
NB: The positive polarity is on the V
Hz terminal
10 - FREQUENCIES
Connect the leads to the multimeter and connect in parallel to
the circuit to be tested.
Set the switch to the Hz function
Digital reading: automatic range selection, kHz is displayed,
read the measured value.
If necessary, press the following keys,
No analogue reading: the needle stays on zero.
- HOLD to hold in memory
- for display backlighting
kHz 4 kHz 40 kHz 100 kHz
Maximum reading 3.999 kHz 39.99 kHz 99.9 kHz
Accuracy 1 % rdg ± 2 counts
Permitted overload 1000 V
8 - CONTINUITY SOUND TEST
Connection and specifications: idem Resistances for 400
range
Place the selector switch on the
function
Continuous audible beep emitted for a resistance R
400
Digital
Analogue
Permitted overload
Max reading
Accuracy
(1)
Max reading
Scale
Accuracy
(2)
Reading
coefficient
400
4 k
40 k
400 k
4 M
40 M
399.9 3.999 39.99 399.9 k 3.999 M 39.99 M
(3)
1% rdg ± 2 counts
(3)
500 5 k 50 k 500 k 5 M 50 M
50
x10 x0.1 x1 x10 x0.1 x1
2.5 %
600 V
(1) As % of the reading (rdg) from 10 to 100 % of the range (2) As % of the end of scale (3) 5%rdg ± 5 counts