Owner manual

- 7 -
3.0 BASIC PROCEDURES
3.1 Turning Power ON and OFF
To turn the gauge on, press and hold the power switch
(item H, page 4) for two seconds, until the chime sounds. The
start screen appears briefly, followed by - - - -. The gauge is
now ready to use.
To turn the gauge off, press and hold the power switch
(item H, page 4) for two seconds, until the chime sounds.
Auto Power Off / Permanent On modes
When in the automatic power-off mode, the gauge will
automatically turn itself off after 90 seconds of non-use.
In the permanent on mode, the gauge will remain on continu-
ously, even during extended periods of non-use. To switch
between modes:
1. Press the key repeatedly until Options shows on the
display.
2. Press OK
3. Press the key repeatedly until Switch Off Mode shows
on the display.
4. Press OK
5. Press the key to select either permanent on or auto switch
off.
6. Press OK to confirm your selection.
NOTE: To cancel a selection and exit from the menu
subsection press ESC.
- 22 -
9.0 SPECIFICATIONS
Range 0 – 60.00 mils (0 - 1500 µm)
Accuracy ±(0.04 mils / 1µm + 1% of reading)
Display Back-lit, 4-digit alphanumeric, digit height
0.4" (10mm)
Minimum
Measuring Area 0.2" x 0.2" (5mm x 5mm)
Minimum
Curvature Radius concave: 0.2" (5mm), convex: 0.12" (3mm)
Minimum
Substrate Thickness 20 mils (0.5 mm)
Calibration Factory calibration, zero calibration, foil
calibration,
Off-set function: addition or subtraction of a
constant value
Memory 80 readings
Statistics Program Number of readings, mean value, standard
deviation, maximum and minimum reading of
max. 10,000 readings
Set Limits Adjustable selectable with acoustic alarm
Data Output Infrared IrDA standard
Operating Temp. 32 °F to 122 °F (0 °C to 50 °C )
Surface Temp. 5 °F to 140 °F (-15 °C to 60 °C )
Storage Temp. -4 °F to 140 °F (-20 °C to +60 °C)
Power 2 AA 1.5V
Dimensions 5.6" x 2.5" x 1.2" (140mm x 562mm x 30mm)
Weight 7 oz (200 g) — gauge + probe
Protection Class IP 52 (proof against dust and dripping water)
Standards DIN, ISO, ASTM, BS
- 7 -
3.0 BASIC PROCEDURES
3.1 Turning Power ON and OFF
To turn the gauge on, press and hold the power switch
(item H, page 4) for two seconds, until the chime sounds. The
start screen appears briefly, followed by - - - -. The gauge is
now ready to use.
To turn the gauge off, press and hold the power switch
(item H, page 4) for two seconds, until the chime sounds.
Auto Power Off / Permanent On modes
When in the automatic power-off mode, the gauge will
automatically turn itself off after 90 seconds of non-use.
In the permanent on mode, the gauge will remain on continu-
ously, even during extended periods of non-use. To switch
between modes:
1. Press the key repeatedly until Options shows on the
display.
2. Press OK
3. Press the key repeatedly until Switch Off Mode shows
on the display.
4. Press OK
5. Press the key to select either permanent on or auto switch
off.
6. Press OK to confirm your selection.
NOTE: To cancel a selection and exit from the menu
subsection press ESC.
- 22 -
9.0 SPECIFICATIONS
Range 0 – 60.00 mils (0 - 1500 µm)
Accuracy ±(0.04 mils / 1µm + 1% of reading)
Display Back-lit, 4-digit alphanumeric, digit height
0.4" (10mm)
Minimum
Measuring Area 0.2" x 0.2" (5mm x 5mm)
Minimum
Curvature Radius concave: 0.2" (5mm), convex: 0.12" (3mm)
Minimum
Substrate Thickness 20 mils (0.5 mm)
Calibration Factory calibration, zero calibration, foil
calibration,
Off-set function: addition or subtraction of a
constant value
Memory 80 readings
Statistics Program Number of readings, mean value, standard
deviation, maximum and minimum reading of
max. 10,000 readings
Set Limits Adjustable selectable with acoustic alarm
Data Output Infrared IrDA standard
Operating Temp. 32 °F to 122 °F (0 °C to 50 °C )
Surface Temp. 5 °F to 140 °F (-15 °C to 60 °C )
Storage Temp. -4 °F to 140 °F (-20 °C to +60 °C)
Power 2 AA 1.5V
Dimensions 5.6" x 2.5" x 1.2" (140mm x 562mm x 30mm)
Weight 7 oz (200 g) — gauge + probe
Protection Class IP 52 (proof against dust and dripping water)
Standards DIN, ISO, ASTM, BS