Owner's manual

20
4.5.1 Measurement range setting
The DT-329 has a selectable measuring range, which can be set in the Parameter mode setting. The
range and resolution of this setting will be different for each measuring range, as indicated in the table
below.
Test unit Measuring range as Indicated in Parameter Settings
FPM
12,000
(range 60.0 - 12,000.0)
120,000
(range 60 - 120,000)
Hz
200
(range 1.000 - 200.00)
2,000
(range 1.00 - 2000.0)
*Note that if the flash range is changed to a lower range, the current flash rate, if larger than 12,000 FPM or
200 Hz, will decrease to the maximum allowable value of the range.
Ex: If flash rate is set to 60,000 FPM in the range of 60 120,000 FPM, it will automatically switch to
12,000 FPM when the flash measuring range parameter is changed to 60.0 12,000.0 FPM. The max
value is limited if the Flashing time (frequency) setting is greater than the range in the test range switch.
To adjust the measuring range parameter, pressPHASE +or turn the dial clockwise to set the range as
120,000 FPM or 2000 Hz
Press PHASE - or turn the dial counter clockwise to set the range as 12,000 FPM or 200 Hz”.
Operation Expression
Measuring range set to
60.0 - 12,000.0 FPM
Measuring range set to
60 - 120,000 FPM
Press and release
Turn clockwise
Turn cou
nter
clockwise
Or
PHASE-
FLASH
PHASE+
FLASH
PHASE-
PHASE+
Press and release
Or
Measuring range set to
60.0 - 12,000.0 FPM
Measuring range set to
60 - 120,000 FPM
Auto Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min Max
min
sec
hHz
ms
Auto Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min Max
min
sec
hHz
ms
Auto Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min Max
min
sec
hHz
ms
Auto Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min Max
min
sec
hHz
ms