Memory function
•Saving the setting value when the power is OFF
•
Saving 5 setting values each on internal oscillation and external synchronous emission respectively
Auto emission stop
Available to set continuous emission, or set the time to stop emission by 1 minute within the range between 1 min and 120 min.
(Set in function mode 3)
Power AC100 to 230V(50Hz/60Hz)
Built-in NiMH battery
•Continuous emission time
Approx. 2 hours (when the emission duration is set to 3.6º)
Approx. 5 hours (when the emission duration is set to 1.0º)
•Charging time: Approx. 2.5 hours
Supplied AC adapter
•Input : AC100 to 230V
•Output : DC24V
Operating temperature 32 to 95 F (0 to 35 ºC)
Operating humidity 35 to 85%RH
Operating environment No dust and/or corrosive gases
Compliance standard RoHS
Protection structure Equivalent to IP65 NEMA 4X
Weight Approx. 4 lb (1.8 kg) Approx. 4.6 lb (2.1 kg)
Standard accessories External I/O connector (8 pin) x 1 Dedicated AC adapter x 1
External dimensions6
[DT-361]
[DT-365]
137
149
213
12
14.4
132
98
103
137
213
12
14.4
149
132
98
103