Manual
10
5.30 Configuring Dip Switches
The DTMB is supplied with six (6) dip switches permitting the user to select
desired Display Update Rate and Memory Mode as detailed below.
To access the dip switches, the Thumbpiece and Slide Guide Plate must be
removed. Refer to access instructions below.
5.31
Accessing The Dip Switch Block
1. Turn the DTMB power off by pressing and holding the  key 
for five (5) or more seconds. The display will go blank.
2. Using a small Phillips screwdriver, remove 
the screw in the center of the Thumbpiece. 
Remove the Thumbpiece and screw. The 
Slide Guide Plate and screw will be visible. 
3. Using a small Phillips screwdriver, remove 
the screw at the bottom of the Slide Guide 
Plate and remove plate.
Display Update Rate
Memory Mode
0.5 sec. 1 sec. 2 sec. 4 sec.
Standard Standard-NAPO
= Denotes Factory Setting Standard N A P O = Standard Memory with No Auto Power Off
POWER
EXIT
Slide Guide
Plate
Thumbpiece
15
6.1
1 Viewing Data in Standard Memory
To view data stored in Standard Memory, press the  key.
The following will be displayed when the  key is pressed repeatedly.
Each time the key is pressed the displayed value will change.
Press the  key at any time to exit the Recall Mode. 
6.12 
To Clear All Data Stored in the Standard Memory
Press the  key and the  key simultaneously
6.20 Standard Memory with No Auto Power Off (Standard - NAPO)
This memory mode is identical to the Standard Memory Mode detailed above,
except that when configured in this mode the power will not turn off
automatically after 90 seconds of inactivity.
MAX
MIN
PEAK
Maximum Value
Last Reading
Minimum Value Peak Value
Action  Display Will Show  LCD Indicator
Press RECALL key Maximum Value  MAX
Press RECALL key Minimum Value  MIN
Press RECALL key Peak Value  PEAK
Press RECALL key Last Reading  none
RECALL
RECALL
POWER
EXIT
STORE
RECALL