User Manual

–11 –
To Stop Data Logging:
1. When you want to stop data logging, press the MEM key once again. The statistical
values are calculated from the logged tension data and stored in the following order:
Average value
Last value
Maximum value (MAX)
Minimum value (MIN)
Minimum peak value (MIN PEAK)
Maximum peak value (MAX PEAK)
The MEM indicator is frozen on the display and the current reading is
displayed. The tension meter has changed back to measuring mode.
To Save The Next Measuring Period:
1. Press the MEM key again. The DISPLAY shows the memory
mode “S” and the next memory number.
6.3 Data Logging in Mode C (Continuous)
1. Turn on the tension meter.
2. Memory Mode C set as described inSec. 6.1
3. Insert process material and begin measuring as described in Sec.4.0.
To Start Data Logging:
1. Press and hold the MEM key until the DISPLAY shows the
memory mode “C” and the current memory number.
2. Release the MEM key. The tension meter starts logging the data.
While the tension data are stored, the MEM indicator blinks on the
DISPLAY and the currently measured value is displayed.
To Stop Data Logging:
1. To stop data logging, press the MEM key once again. The statistical values are
calculated and stored in the following order:
Average value
Last value
Maximum value (MAX)
Minimum value (MIN)
Minimum peak value (MIN PEAK)
Maximum peak value (MAX PEAK)
Tension Value - 1 -
Tension Value - 2 -
Tension Value - N - (up to 4000 tension values in up to 255 measuring periods)
3
Mem cN
3
Mem cN
S 2
Mem cN
C 1
cN
– 26 –
3. Unscrew and remove the GUIDE ROLLERS (2) using
the supplied open-end wrench (4mm jaw width).
Note: Should any of the three threaded studs be damaged,
replace it with one of the threaded studs supplied with the
new rollers.
4. Carefully screw the new GUIDE ROLLERS onto the
ROLLER SHAFTS.
5. Carefully tighten the new rollers with the open end
wrench until hand tight.
Note: When loosening or tightenng the rollers, steady
the roller bolt with the supplied screwdriver to prevent
the ROLLER SHAFTS from being twisted off.
6. Slide the FILAMENT
GUIDE up the roller
shafts in the direction
of the arrow.
7. Push the FILAMENT GUIDE upwards far
enough to ensure that the rollers do not rub
against the FILAMENT GUIDE and that
the process material can slide unhindered
from the FILAMENT GUIDE into the
roller grooves.
8. Tighten the SETSCREWS (2) with the
supplied screwdriver (1.5mm blade).
Ideal line
ROLLER SHAFTS