User Manual

– 5 –
2.6 Zero Adjustment of the Measuring Position (Auto Zero)
A Zero Adjustment is automatically carried out for the current measuring postion.
A Zero Adjustment must be carried out whenever the tension meter
does not display “0” in measuring position. The process material must
not yet be inserted!
Procedure:
1. Switch on the tension meter as described in Sec 2.3.
2. Select the unit of measure as described in Sec 2.5.
Do not insert the process material.
3. Hold the tension meter in the desired measuring position. Be careful to hold the
instrument absolutely steady.
4. Press the POWER key.
The DISPLAY momentarily shows and then switches to .
The tension meter is now adjusted for the new material path and is ready to measure.
– 32 –
A Button READ Section 3.7
B Choice box SCALE Section 3.8
C Button AUTOSCALE Section 3.8
D Display POSITON IN MEMORY Number of saved series of measurement
E Choice box SELECTED POSITION Selected series of measurement
F Button RESET Section 3.8
G Display MEMORY MODE Used memory mode during the
measuring
H Button ZOOM Section 3.8
I Display UNIT measuring unit of the readings
J Display DEVICE TYPE Display the connected unit
K Display STATISTICS Statistical data of the displayed series of
measurement
L Button SAVE Section 3.10
M Button GENERATE Section 3.9
N Display TENSION Readings as graph
O Button EXPORT TO EXCEL Section 3.9
P Button CLOSE Close MEMORY-REVIEW