Function Setting
The FGE/V-X will default to certain parameters when power is turned OFF and ON. To access the function setting:
1. Press and hold the ZERO button.
2. Press and release the POWER button.
3. Each time the PEAK button is pressed, the FGE/V-X will scroll through each of the functions.
4. Press the ZERO button to exit.
F01
0001
OFF
F01
-0001
F02
3
F03
10
F04
2400
F02
5
F02
10
F02
20
F02
1
F02
2
F02
3
F03
OFF
F04
4800
F04
9600
F04
19200
UNIT
Press and hol d ZE R O but ton. Pr ess and rel ea se the P OWE R butt on. -> Se e Fi g.3
PEAK
PEAK
PEAK
PEAK
F01
0001
Minus Plus
Plus or mi nu s sign
Display updat e time
**
Au to power off
Baud r ate of
RS2 32C
F03
10
F04
2400
Plus or mi nu s sign
ZERO
Data w as memoried.
UNIT
UNIT
UNIT
UNIT UNIT
UNIT
UNIT
UNIT
UNIT
UNIT UNIT
UNIT
UNIT
UNIT UNITUNITUNIT
**Note: In function 2, the numbers sign ify as follows.
1; 1 time/sec, 2; 2 times/sec, 3; 3 times/sec, 5; 5 times/sec, 10; 10 times/sec, 20; 20 times/sec
Data was memorized