  If the file size more than 32 bytes, you'll see warning window (Figure 15), 
 what telling that first 32 bytes ONLY from the file will copy into the incremental 
 area of the target M35080/M35160 memory. 
Numeric display message 
“ ri“ - read incremental registers: 
Numeric display message 
“ Li“ - write incremental registers: 
4.5 ERASE : AU mode 
 Practical steps:  
1.  Re-mount mode jumper to “ AU“ position (Figure 2) 
2. Make sure that “Function” jumper mounted to 160 or 080 position 
NOTE: 160 position:M35080; D160D0WQ; D080D0WQ devices 
   080 position: M35080-3; M35080-6 devices 
3. Turn ON the M35160 Eraser/Programmer, insert jack plug into power jack 
4. Install the target device into the target socket (M35160 marked) 
 Notice: 1-pin on the target socked and programming adapter "◙" marked, 
   which point towards pin 1 of the device (Figure 3) 
5. Make sure that numeric display message matches to this one: 
“ AU“ 
Figure 16 
Status message --> 
Status message --> 
Step 6 
Press RS button 
Press WR button 
Function jumper 
Step 2 
Step 7 