User's Manual

SIDEP
Page 11 of 19
3 Selection of Functioning Modes with DIP Switch:
Switch
Number
Description
Switch 1
Cable Synchro Setting
ON: Master board
OFF: Slave board
Switch2
Power Synchro Mode
ON: Power synchronization(up to 4 systems on same
power line)
OFF: Power synchronization(up to 2 systems on separated
power line)
Switch 3
Synchro Increment – 5
th
systems
ON: Over 4 multiple systems synchronized by cable, every
5th system synchronized should have be on
OFF: At most 4 systems synchronized
Switch 4
Deactivator Synchro Mode
ON: Pulse Deactivator (SPD82) is synchronized by cable
Master board when cable synchronization
OFF: No deactivator
Switch 5
Tag/Noise Level Mode
ON: Normal sensitivity – Low noise environment
OFF: Low sensitivity – High noise environment
Switch 6
Sensitivity reduction Mode
ON: Standard System Sensitivity
OFF: Low Sensitivity
Switch 7
Automatic Level Mode
ON: The sensitivity level is automatically regulated
according to environment noise variation
OFF: The sensitivity is set by VR5
Switch 8
Deactivable Labels Protection Mode
ON: The transmission power level will automatically
decrease once a label is detected in order to avoid
deactivation of the label by the EAS system
OFF: Transmission power level Stable (recommended for
hard tag only system).
Default setting:
1 2 3 4 5 6 7 8
on off off off on on off off