User's Manual

SIDEP
Page 12 of 19
4. Basic Adjustment Procedure:
Basic adjustments procedure should be sufficient to set all necessary
parameters.
Other advanced adjustments and modification should be performed by
experienced technicians.
All other advanced parameters are set at factory and in most case the basic
adjustments method below would be enough to optimized the MONO system
performance.
4.1 Single System Adjustment
Set Switch 7 in position OFF (Automatic Level Mode Off).
Press SW1 to reset system.
Wait 1 minute for DSP to reboot.
Find the best position of antenna (lower LED Noise Bar Level).
Refer to previous instructions to find source of disturbance if the noise level
is high.
If necessary reduce VR5 to have less than 4 LED on (only green Led should
be on and 1 orange blinking).
Put back Switch 7 in Position : On
Press SW1 to reset system.
Wait 1 minutes for DSP to reboot.
5. Multiple System Synchronization
There are 3 different ways to synchronized multiple systems. As much as
possible try to use the external Synchro cable RG174 to synchronized multiple
systems. This method provides the most reliable synchronization. DS2 will be
lighted.