Reduce the system sensitivity with VR5 until this problem stops.
Then switch the system back to the automatic level control mode (switch 7
position ON)
Press SW1 to reset system.
The detection will decrease, but functioning will be more stable and false
alarm less frequent.
External Synchro Mode is not working even if cables are properly
connected (EXT SYN LED ON except Master System): A slave system must
have been powered on before its Master.
Switch off all systems
Switch on each system individually and in order starting from the Master
system.
Labels are deactivated when passing near the MONO system:
Set Switch 8 in the position ON.
Press SW1 to reset system
To protect the label against deactivation due to high transmission Level, the
system will automatically decrease the output Transmission Level when a tag is
detected
System reaction may be slower and detection performance reduced.
7. Advanced adjustment of system parameters
7.1 LEDs DS11-18:
Press the SW2 button while holding it , you can see the signal number
corresponding the list below. When you release it you can see the value.
Number of LEDs being ON simulates the output of a particular signal .
input signal (default after powering the system on)
filtered input signal
level of resonance caused by tags, metal construction, loops of wire,
etc)
resultant input signal
signal detection on each frequency (there are 8 frequencies transmitted)
not yet used
not yet used
indication of sensitivity level reduction in automatic regime (DIP 7 ON).
(Example: 6 LEDs ON…80% of maximum or reduction by 20%)