Installation Manual
Table Of Contents
- Statements
- Guide Conventions
- 1
- Background
- F10 System Hardware
- System Diagrams
- Grouping Multiple Antennas
- 2 x 1 Meter Configuration
- 2
- Antenna Distance from Interfering Elements
- System Performance Considerations
- Determining the Electronics Location
- Environmental Considerations
- Site Survey Conclusion
- 3
- Requirements
- Installation Outline
- F10, 1 Meter and 2 Meter Floor Cuts
- Common Wider Floor Cuts
- Mounting the Electronics Enclosure
- Mounting the Power Supply
- Finishing Installation
- 4
- Antenna Wiring
- Wiring the 2 x 1 Meter System
- Overview
- Wiring Between F10 Systems for Sync
- Wiring peripherals
- 5
- System Setup Using DMS
- Application-Based Detection Modes
- Alarm Severity
- Configuring SAM (Smart Alarm Management)
- Updating the System
- 6
- TR4215 Features
- Basic Tuning Methods Using DMS
- Noise Sources
- Analog View
- Evaluate Jumper Positions
- Configuring the System for Asynchronous Noise
- Resonance Sources
- Data Retrieval
- A
- Power Supply Details
- B
- F10 Parts List
- C
- F10 System – Proximity to Deactivation Units
- F10 System – Proximity to Other Systems
- D
- F10, 2 Meter System
- F10, 1 Meter System
F10 Installation Manual Rev. *60 24 of 71
Finishing Installation
Wiring the electronics, and configuring and tuning the antennas must occur before finishing the
physical installation. Proceed to Chapters 4, 5 and 6, complete the setup and validation, and then
return to this section when ready to finish the physical installation.
Filling Trenches
The floor cuts or cavities are filled with concrete mortar, grout, and/or sealants during this final
step, ensuring the antenna locations are not visible. It is crucial that the grout be non-metallic and
non-magnetic. Occasionally (F10 system below wooden flooring), the antenna system is not
covered by Checkpoint personnel, as it will later be covered with flooring. Protect, as necessary.
The F10 system has been tested and is approved to be used with the following concrete repair
mortars and mixes:
1. Ardex TRM – Transportation Repair Mortar
2. QUIKRETE® Concrete Mix (No. 1101)
3. QUIKRETE® Fast-Setting Concrete Mix (No. 1004)
Note: Detection performance of the system may be temporarily affected by the water content in the repair
mortar. As the mortar mix cures, detection performance improves.