Installation Manual
Table Of Contents
- Statements
- Guide Conventions
- 1
- Background
- F10 System Hardware
- System Diagrams
- Grouping Multiple Antennas
- 2 x 1 Meter Configuration
- 2
- Antenna Distance from Interfering Elements
- System Performance Considerations
- Determining the Electronics Location
- Environmental Considerations
- Site Survey Conclusion
- 3
- Requirements
- Installation Outline
- F10, 1 Meter and 2 Meter Floor Cuts
- Common Wider Floor Cuts
- Mounting the Electronics Enclosure
- Mounting the Power Supply
- Finishing Installation
- 4
- Antenna Wiring
- Wiring the 2 x 1 Meter System
- Overview
- Wiring Between F10 Systems for Sync
- Wiring peripherals
- 5
- System Setup Using DMS
- Application-Based Detection Modes
- Alarm Severity
- Configuring SAM (Smart Alarm Management)
- Updating the System
- 6
- TR4215 Features
- Basic Tuning Methods Using DMS
- Noise Sources
- Analog View
- Evaluate Jumper Positions
- Configuring the System for Asynchronous Noise
- Resonance Sources
- Data Retrieval
- A
- Power Supply Details
- B
- F10 Parts List
- C
- F10 System – Proximity to Deactivation Units
- F10 System – Proximity to Other Systems
- D
- F10, 2 Meter System
- F10, 1 Meter System
F10 Installation Manual Rev. *60 26 of 71
Antenna Wiring
Wiring Components
The components involved in Antenna Wiring and Coax Cable routing are shown below.
Note: The Impedance
Matching Board (right)
only fits in the junction
box in one position. Do
NOT it force into place.
Placement
Unpack the antenna(s). Each antenna has four (4) colored wires that stick out from an end.
1. Apply the rubber o-ring over the threads of the ½” inch male fitting. Do NOT apply PVC
cement. Feed the antenna wires through the male fitting, then tighten. Screw one (1) fitting in
per antenna until rubber o-ring is compressed.
2. Position the antenna(s) in the floor trough, carefully lowering each into place.
3. Install the 1/2” ENT tubing (conduit). The tubing must cover the entire coax cable run from
the electronics to the antennas. Cut the tubing as required.