Installation Manual
Table Of Contents
- Statements
- Guide Conventions
- 1
- Background
- F10 System Hardware
- System Diagrams
- Grouping Multiple Antennas
- 2 x 1 Meter Configuration
- 2
- Antenna Distance from Interfering Elements
- System Performance Considerations
- Determining the Electronics Location
- Environmental Considerations
- Site Survey Conclusion
- 3
- Requirements
- Installation Outline
- F10, 1 Meter and 2 Meter Floor Cuts
- Common Wider Floor Cuts
- Mounting the Electronics Enclosure
- Mounting the Power Supply
- Finishing Installation
- 4
- Antenna Wiring
- Wiring the 2 x 1 Meter System
- Overview
- Wiring Between F10 Systems for Sync
- Wiring peripherals
- 5
- System Setup Using DMS
- Application-Based Detection Modes
- Alarm Severity
- Configuring SAM (Smart Alarm Management)
- Updating the System
- 6
- TR4215 Features
- Basic Tuning Methods Using DMS
- Noise Sources
- Analog View
- Evaluate Jumper Positions
- Configuring the System for Asynchronous Noise
- Resonance Sources
- Data Retrieval
- A
- Power Supply Details
- B
- F10 Parts List
- C
- F10 System – Proximity to Deactivation Units
- F10 System – Proximity to Other Systems
- D
- F10, 2 Meter System
- F10, 1 Meter System
F10 Installation Manual Rev. *60 34 of 71
Remote Voice Alarm
1. Connect the remote voice alarm wiring as shown below (or refer to Table 4.3).
Figure 4.2 Electronics Wiring: Alarm Group Relay
Note: Sync connections are shown. Not all systems will be synced.
Remote Voice Alarm / Alarm Counter
Wire Color TR4215 Connections
WHITE (RLY) J9-5
GREEN (RLY) J9-6
RED (+24V DC) J18-3
BLACK (Ground) J18-1
Table 4.3 Alarm Group Wiring Connections
2. Install the device and complete wiring at the peripheral device(s).
Refer to the peripheral’s Installation Instructions.