Installation Manual
Table Of Contents
- Statements
- Guide Conventions
- 1
- Background
- F10 System Hardware
- System Diagrams
- Grouping Multiple Antennas
- 2 x 1 Meter Configuration
- 2
- Antenna Distance from Interfering Elements
- System Performance Considerations
- Determining the Electronics Location
- Environmental Considerations
- Site Survey Conclusion
- 3
- Requirements
- Installation Outline
- F10, 1 Meter and 2 Meter Floor Cuts
- Common Wider Floor Cuts
- Mounting the Electronics Enclosure
- Mounting the Power Supply
- Finishing Installation
- 4
- Antenna Wiring
- Wiring the 2 x 1 Meter System
- Overview
- Wiring Between F10 Systems for Sync
- Wiring peripherals
- 5
- System Setup Using DMS
- Application-Based Detection Modes
- Alarm Severity
- Configuring SAM (Smart Alarm Management)
- Updating the System
- 6
- TR4215 Features
- Basic Tuning Methods Using DMS
- Noise Sources
- Analog View
- Evaluate Jumper Positions
- Configuring the System for Asynchronous Noise
- Resonance Sources
- Data Retrieval
- A
- Power Supply Details
- B
- F10 Parts List
- C
- F10 System – Proximity to Deactivation Units
- F10 System – Proximity to Other Systems
- D
- F10, 2 Meter System
- F10, 1 Meter System
F10 Installation Manual Rev. *60 41 of 71
Configure to ECO Mode
1. Using the DMS tool, connect to the TR4215 board. Figure 5-3 shows the opening screen
with the Network view expanded to show all devices.
Figure 5.3 DMS Network and Task Manager View
2. Navigate to the Switch Settings window (click Configure Settings, shown above).
3. Under the Detection Tab, fill in the following parameters:
• RF Group Address: choose an Address between 1 and 6. The address should
match any other reader.
• Sync Mode: set to "ECO Mode" for the F10, 1 meter system or 2 x 1m system.
For the 2 meter system, set the sync mode to “Detector” or “Primary Non ECO.”
• TX Control: set to Enabled, Mode 2.
Figure 5.4 Detection Tab, Switch Setting Parameters