Installation Manual
Table Of Contents
- Statements
- Guide Conventions
- 1
- Background
- F10 System Hardware
- System Diagrams
- Grouping Multiple Antennas
- 2 x 1 Meter Configuration
- 2
- Antenna Distance from Interfering Elements
- System Performance Considerations
- Determining the Electronics Location
- Environmental Considerations
- Site Survey Conclusion
- 3
- Requirements
- Installation Outline
- F10, 1 Meter and 2 Meter Floor Cuts
- Common Wider Floor Cuts
- Mounting the Electronics Enclosure
- Mounting the Power Supply
- Finishing Installation
- 4
- Antenna Wiring
- Wiring the 2 x 1 Meter System
- Overview
- Wiring Between F10 Systems for Sync
- Wiring peripherals
- 5
- System Setup Using DMS
- Application-Based Detection Modes
- Alarm Severity
- Configuring SAM (Smart Alarm Management)
- Updating the System
- 6
- TR4215 Features
- Basic Tuning Methods Using DMS
- Noise Sources
- Analog View
- Evaluate Jumper Positions
- Configuring the System for Asynchronous Noise
- Resonance Sources
- Data Retrieval
- A
- Power Supply Details
- B
- F10 Parts List
- C
- F10 System – Proximity to Deactivation Units
- F10 System – Proximity to Other Systems
- D
- F10, 2 Meter System
- F10, 1 Meter System
F10 Installation Manual Rev. *60 47 of 71
Table 5.1 Alarm Priority Descriptions
Configuring SAM (Smart Alarm Management)
This chapter details the steps and options for configuration of the Smart Alarm Management
(SAM) system in DMS.
Note: For information on installation and use of the DMS system, refer to the Field Service Diagnostic
Management User’s Guide.
Navigating to the SAM Screen
1. DMS should still be connected to the desired TR4215 reader.
2. Navigate to the Access screen (shown in Figure 5.9), which describes the current settings for
the antenna(s) in the group.
Note: Although previous Liberty systems required the "TR4024/26" Device setting in the DMS Connection
Settings window, NGL uses the "Evolve" Device connection.
Frequency Band
Tag
Frequency
Alarm
Severity
Tag
Frequency
Alarm
Severity
Primary
Secondary
Standard: 8.2
8.2
M
-
-
Library: 9.5
9.5
M
-
-
Immunity: 8.2
8.2
M
-
-
Corral: 8.2, 9.0
8.2
M
9.0
H
Rev Corral: 9.0, 8.2
9.0
M
8.2
H
Apparel: 8.2, 9.2
8.2
M
9.2
H
Japan1: 8.2=9.5
8.2
M
9.5
M
Japan2: 8.2, 9.5
8.2
M
9.5
H
Pharma: 8.2, 7.2
8.2
M
7.2
C
RazorKeeper: 8.2, 7.2
8.2
M
7.2
H