Wiring between Chassis Box /SSB
There are only two (2) wires connected Chassis and SSB. They are 1) RG59 coax cable and 2)
SSB Light/Sounder cable (22 AWG 4-conductors (STP) (5594)/2-conductors 22 AWG B 8442
RG59 Coax Cable:
A 26ft long, two end pre-terminated RG59 coaxial cable is packed with SSB antenna. It connects
the Chassis Box antenna (SSB). It is recommended to leave the one pre-terminated end with 3-pin
Connector at the SSB, another pre-terminated shield end to Chassis Box. (Refer to Figure 6 metal-
shield end)
Figure 6 metal-shield end
SSB Light/Sounder Cable
It is recommended to use CKP standard 4-conductor wire(7102900) and 2-condutior
wire(7045353). For details connection , please refer to the table below :
Primary SSB Light/Sounder Cable Wiring Table
4 conductor wire
Wire Color Chassis Box
Classic IP Style SSB
1
WHITE J42-LTS+ LT Blue
GREEN J41-LTS+ LT Red
RED J18 Power + LT Power +
BLACK J18 Power - LT Power -
2 conductor wire
RED J11 SND 1+ SD +
BLACK J11 SND 1- SD -