Installation Guide Part 2

NGL FX Installation Manual Rev. *
44 of 84
C H A P T E R
6
NGL SYSTEM CONFIGURATION VIA DMS
Overview
This chapter reviews the DMS configuration steps for the FX system using DMS.
Antenna tuning including coupler jumper setting is covered in Chapter 7: NGL Tuning. Please
follow this tuning guide to optimize the system performance after completing the system
configuration.
Note: Please use DMS version 1.8.31 and later. TR4215 firmware version must be 4.00 and
later.
System Setup Using DMS
The following sections describe the basic NGL setup under two different aisle configurations:
Single-Aisle and Multi-Aisle. In either case, the basic setup is similar but an extra step is needed
for Multi-Aisle configuration.
The instructions below emphasize which parameters should be setup for the TR4215 board. It
does not go into detail about using the DMS tool or how to navigate to the specified setup
Windows. A basic knowledge of the DMS tool is assumed.
Note: Please refer Field Service Diagnostic Management User Manual for general help with
using the DMS tool.
Basic setup
The basic setup process consists of following steps:
1. Make a new DMS connection – for new installation
2. Configure PAB/SAB (coupler) operation mode
Make a New DMS Connection
3. Connect the service PC laptop to the serial port on the TR4215 board.
4. Launch the DMS program (version 1.8.31 or later) and enter your login information.
5. Make a new Connection for connecting to the TR4215 board. Be sure to select "(Direct)
Serial" for the Type and "Evolve" as the Device.
Unlike previous Liberty Systems, NGL does not use the "TR4024/26" Device Connection.
Figure X*** New Connection Setup shows the "Add Connection" window with the
appropriate NGL settings.