User's Manual
Classic Style Installation Manual Rev. *60
11 of 27
C H A P T E R
3
PHYSICAL INSTALLATION
Overview
This chapter covers the physical placement and installation of the TR4215 antennas and power
supply in the following sections:
1. Placement: How to determine the proper placement of the antennas.
2. Power Supply: Information on typical power supply placement.
3. Wire Routing: Information on typical wire routing methods.
4. Antenna Mounting: Antenna mounting information.
Note: For details of placement, refer to NGL installation manual, CKP P/N 7360602.
Aisle Width
The maximum aisle width for the Classic Style antennas (with 410EP tag) is:
Classic Style antennas (PSB/SSB) – 1.8 m [6 ft]
Classic Style antennas are composed of:
Pedestal Classic Style NGL PSB (call it PSB for short, CKP P/N 10104118)
Pedestal Classic Style NGL SSB (call it SSB for short, CKP P/N 10104133)
System performance is affected by aisle width and tag type. For aisle width details please refer to
the TR4215 Product Reference Guide.
Power Supply
Classic Style with coupler antennas utilizes a +24 VDC power supply.
Placement
The power supply can be placed near the system, under a cashwrap counter, under shelving, above
the drop ceiling (if using plenum-rated cabling), or in a nearby utility closet.
Placement Requirements:
The power supply must be within 18m [60ft] of the furthest antenna.
The power supply must be placed no higher than what is accessible from a store ladder.