User's Manual
Table Of Contents
363325 Rev. 01 Page 8 of 9
Controls (refer to Figure 4)
OPERATE BUTTON RED button, press to operate; release when finished.
MODE SWITCH Slide switch located on the left side of the unit. This allows the user to operate either in the
PV (Portable Tag Verifier) or DV (Portable Deactivation Verifier) mode.
FREQ. SEL.SWs. Two rotary switches located on the right side of the unit. This allows the user to select
which type of tags he/she wishes to detect.
Indicators (refer to Figure 4)
MODE The YELLOW indicator illuminates when the Omni verifier is in DV (portable deactivation
verifier) mode.
NOISE The ORANGE indicator illuminates when the Omni verifier detects a high noise
environment. This indicator will only light while in the PV (portable tag verifier) mode.
The detection height of a tag could be affected when this indicator is illuminated.
ALARM/CHG The RED indicator illuminates when a tag is detected in PV mode. The RED indicator also
illuminates once the Omni has determined that the Counterpoint antenna is emitting enough
energy to deactivate a standard tag in DV mode. Additionally, while in the Docking
Station, a blinking RED light indicates a deeply discharged battery. When the RED
indicator is lit continuously, this indicates normal charging operation. After charging is
complete, the RED indicator turns off.
PWR/LO BAT The GREEN indicator illuminates continuously while the RED operate button is pressed.
Additionally, this GREEN indicator will flash when the battery is low. The Omni verifier
should be placed in the docking station as soon as possible.
BUZZER Sounds when a tag is detected in PV (portable tag verifier) mode. A loud beep indicates a
primary tag and softer beep indicates a secondary tag. When in the DV (portable
deactivation verifier) mode, the buzzer will beep loudly when a valid Checkpoint
Counterpoint deactivator is detected. When in PD (portable deactivator) mode, the buzzer
will beep loudly on a label until it is deactivated (available only with the Omni
Deactivation package).
If the Omni verifier detects an error condition, all the indicators (YELLOW, ORANGE, RED, and GREEN) will flash
simultaneously and the buzzer will sound. The unit will not function. Selecting an invalid frequency setting usually causes this.