Product Info
TUNING PROCEDURE TR4022
____________________________________________________________________________________________________________________________
CHECKPOINT SYSTEMS, INC. CONFIDENTIAL AND PROPRIETARY INFORMATION, FOR INTERNAL USE ONLY.
Rev. 00 Page
7
Table 1: Jumper Definitions
Jumper Label Function
J12 Alarm Group On: Will allow all the alarm group relays to
close when any pedestal within the group
alarms.
Off: Will not allow the alarm group signal to
pass to the next pedestal.
J16 (NO LABEL) Engineering Jumper.
The access panel must be removed to set all of the above jumpers
Table 2: Pushbutton Switch Definitions
Switch Function
SW-1 Reset software
SW-2 Screen select.
SW-3 Screen recall.
Depressing SW2 repeatedly will allow you to toggle from Screen 1 thru Screen 7. The second
pulse of the display found at the DAC test point TP16 identifies the screen being observed. See
Screen 1 on page 11.
Depressing and holding SW3 will cause the display at the DAC test point TP16 to show the
results of the last alarm for the screen being viewed.