User Manual
SGS-P-7.4-01-F02-CTS
This document is issued by the Company under its General Conditions of Service accessible at
http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein.
Any holder of this document is advised that information contained hereon is solely limited to visual examination of the safely and readily accessible portions of the
consignment and reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is
to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
[Rev.:01 Mar.10
th
2014] Page 3 of 16
4.11 Power consumption check at
120V~ 60Hz
125
Pass
1623 ~ 1705W
Not exceed 1.15 times
rated wattage
4.12 Stand-by wattage check 125
0.7-0.8W SGS WI
4.13 Cooking mode check 125
Pass SGS WI
4.14 LCD /light indicator check 125
Pass
SGS WI
4.15 Switch / button function check 125
Pass
SGS WI
4.16 Small object protect function check
125
Pass SGS WI
4.17 Timer / alarm function check 125
Pass SGS WI
4.18 Thermostat function check (dry boil
test)
3 Pass
SGS WI
4.19 Power cord strain relief test 3 Pass 35lbs 1min
4.20 Stability test 3 Pass
15 degree inclined
plane
4.21 Rubbing test 3 Pass
15S water and 15S
alcohol
4.22 Normal running test (simulated as
actual using) for 4 hours
3 Pass
At 120Vac/60Hz with
water
4.23 Actual oil temperature test at
465°F setting
3
Data:
457°F -462°F
SGS WI
4.24 Actual oil temperature test at
140°F setting
3
Data:
131°F -135°F
SGS WI
4.25 Auto shut off time measurement 3 Pass SGS WI
4.26 Time accuracy test 3 Pass
SGS WI
4.27 Thermo fuse response test 1 Pass
SGS WI
4.28 Internal workmanship and
component check
3 Pass
SGS WI
4.29 Noise level measurement 3 Pass SGS WI
4.30 Bar code scanning check 3 Pass SGS WI
4.31 Power supply cord length
measured
3
Data:
148.0-149.0cm
SGS WI
4.32 Product dimension & net weight
check
1
Data:
28.2x35.2x6.8cm / 2.38kg
SGS WI
4.33 Export carton dimension & gross
weight check
Data:
38.7x33.0x43.5cm / 11.11kg
SGS WI
4.34 Export carton drop test 1 Passed
61cm height on one
corner, three edges and
six faces
4.35 Gift box drop test 1 Passed
76cm height on one
corner, three edges and
six faces(client’ spec)
Marking on key components:
Marking on power plug 1 KAI HUA KH-9921 E254267 CSA
cULus
CDF
Marking on power cord 1 UL E254458 HPN
2x14AWG(2.08mm2) VW-1 105C
300V HEATER CORD KAIHUA
CUL E254458 HPN
2x2.08mm2(14AWG) 105C 300V
FT1
CDF
Marking on main PCB 1
JDL-C168A YM-6 UL 94V-0 ROHS
CDF