User Manual
SGS-P-7.4-01-F02-CTS
This document is issued by the Company under its General Conditions of Service accessible at
http://www.sgs.com/terms_and_conditions.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein.
Any holder of this document is advised that information contained hereon is solely limited to visual examination of the safely and readily accessible portions of the
consignment and reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is
to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
[Rev.:01 Mar.10
th
2014] Page 5 of 16
7.9 Carton number was found on export carton and the range as: 1-500. (provide by factory)
8. Inspection Environment:
Lighting : Daylight
Sufficient
Inspection place : Factory workshop
Inspection done on: Table
Cleanliness : Clean
Weather condition: Dry
9. Attachment
Remark photos:
Actually found
PCB
Remark:
Actually found the current fuse was “250V 15A” which conform to ETL test report, but “250V 10A”
was printing on PCB.
Actually found
Instruction manual
Remark:
For timer function: actually found the time can be adjusted from 1minute to 3hours, but the
instruction manual stated as 2hours and 59minutes.
Defect
photos
: