User`s guide

Chapter IX. FCoE Full Offload Initiator
Chelsio T5/T4 Unified Wire For Linux Page 154
iv. Enabling DCBX:
switch(config)# interface ethernet 1/13
switch(config-if)# priority-flow-control mode auto
switch(config-if)# flowcontrol send off
switch(config-if)# flowcontrol receive off
switch(config-if)# lldp transmit
switch(config-if)# lldp receive
switch(config-if)# no shutdown
v. On the FC Ports, if a FC target is connected then perform the following steps -
switch(config)#vsan database
switch(config-vsan-db)#vsan 2
switch(config-vsan-db)# vsan 2 interface fc 2/2
switch(config-vsan-db)#exit
switch(config)interface fc 2/2
switch(config-if)# switchport mode auto
switch(config-if)# switchport speed auto
switch(config-if)# no shutdown.
vi. If you have not created a zone then make sure the default-zone permits the VSAN created,
otherwise the initiator and the target on that particular VSAN although FLOGIā€™d into the
switch will not talk to each other. To enable it, execute the below command.
switch(config)# zone default-zone permit vsan 2
4.1.3. Configuring the Brocade 8000 switch
i. Configure LLDP for FCoE.Example of configuring LLDP for 10-Gigabit Ethernet interface.
switch(config)#protocol lldp
switch(conf-lldp)#advertise dcbx-fcoe-app-tlv
switch(conf-lldp)#advertise dcbx-fcoe-logical-link-tlv